TE525-QD Rain Gage with 6 in. Orifice for RAWS-F Station

概述

The TE525-QD, manufactured by Texas Electronics, has a 6 in. orifice and measures rainfall in 0.01 in. (0.254 mm) increments. The TE525-QD funnels precipitation into a bucket mechanism that tips when filled to a calibrated level.

Note: In the illustration, the rain gage is shown with a pole, which is sold separately.

Read More

The "-QD" version of this product has a cable that terminates in a military style connector (instead of pigtails) and is the ideal length for attachment to a RAWS-F Fire Weather Quick Deployment Station.


Images

Detailed Description

对于此版本的TE525雨量,电缆具有军用连接器而不是尾纤。连接器连接到Raws-F火天气快速部署站。TE525-QD有一个6“孔口,以0.01英寸的增量测量降雨量。TE525-QD FUNNELS沉淀成填充到校准水平时提示的铲斗机制。

Specifications

Sensor Type 折叠铲斗/磁性簧片开关
材料 Anodized aluminum
Operating Temperature Range 0°至50°C
解决 1提示
Volume per Tip 4.73 ml/tip (0.16 fl. oz/tip)
每天降雨量 0.254 mm (0.01 in.)
准确性 1.0%最多2 in./h(50 mm / h)
电缆类型 2-conductor shielded
Funnel Collector Diameter 15.4 cm (6.06 in.)
高度 24.1 cm (9.5 in.)
Cable Length 233.68 cm (92 in.)
Cable Weight 0.1 kg (0.2 lb) per 3.05 m (10 ft) length
Tipping Bucket Weight 0.9 kg (2.0 lb)

Compatibility

The military style connector attaches to the RAWS-F Fire Weather Quick Deployment Station, which has an on-board CR1000.


Frequently Asked Questions

Number of FAQs related toTE525-QD:5

展开全部全部收缩

  1. 信息包含在校准表differs with each sensor. For some sensors, the sheet contains coefficients necessary to program a data logger. For other sensors, the calibration sheet is a pass/fail report.

  2. Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:

    • An –LC model has a user-specified cable length for connection to an ET107, CS110, or retired Metdata1.
    • An –LQ model has a user-specified cable length for connection to a RAWS-P weather station.

    If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field in the product’s Ordering information. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.

    如果电缆用特殊连接器终止用于唯一系统,则型号的末尾指定哪种系统。例如,034B-ET模型将传感器指定为ET107系统的034B。

    • -et模型与ET107气象站的连接器终止。
    • –ETM models terminate with the connector for an ET107 weather station, but they also include a special system mounting, which is often convenient when purchasing a replacement part.
    • –QD models terminate with the connector for a RAWS-F Quick Deployment Station.
    • –PW models terminate with the connector for a PWENC or pre-wired system.
  3. 并非每个传感器都有不同的电缆终端选项。可以通过在传感器产品页面的“排序信息”区域中查看两个位置来检查特定传感器的选项:

    • Model number
    • 电缆终止选项列表

    如果在-ET中提供传感器,-ETM,-LC,-LQ或-QD版本,则该选项的可用性反映在传感器型号中。例如,034b作为034b-et,034b-etm,034b-lc,034b-lq和034b-qd提供。

    如果有可用的所有其他电缆终端选项将列在“电缆终止选项”下的传感器产品页面的“订购信息”区域上列出。例如,034B-L风装置具有-CWS,-PT和-PW选项,如034B-L产品页面的排序信息区域所示。

    Note:As newer products are added to our inventory, typically, we will list multiple cable termination options under a single sensor model rather than creating multiple model numbers. For example, the HC2S3-L has a –C cable termination option for connecting it to a CS110 instead of offering an HC2S3-LC model.

  4. This depends on the information contained in the calibration sheet:

    • 如果校准表包含系数信息,Campbell Scientific会保留副本,并且可以请求替换副本。
    • 如果校准表不包含系数,则Campbell Scientific不会保留副本。可以联系原始制造商以进行替换副本。
  5. Many Campbell Scientific sensors are available with different cable termination options. These options include the following:

    • -pt(-pt w / tinned wirs)选项是默认选项,并在产品行上显示其他选项。电缆终止于直接连接到数据记录器的尾纤。
    • In the –C (–C w/ET/CS110 Connector) option, the cable terminates in a connector that attaches to a CS110 Electric Field Meter or an ET-series weather station.
    • In the –CWS (–CWS w/CWS900 Connector) option, the cable terminates in a connector that attaches to a CWS900-series interface. Connection to a CWS900-series interface allows the sensor to be used in a wireless sensor network.
    • In the –PW (–PW w/Pre-Wire Connector) option, the cable terminates in a connector that attaches to a prewired enclosure.
    • 在-RQ(-RQ W / RAWS连接器)选项中,电缆终止于连接到Raws-P永久远程自动化气象站的连接器中。

    Note:The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact Campbell Scientific for assistance.

Privacy Policy Update

We've updated our privacy policy.了解更多

Baidu