The TE525-QD, manufactured by Texas Electronics, has a 6 in. orifice and measures rainfall in 0.01 in. (0.254 mm) increments. The TE525-QD funnels precipitation into a bucket mechanism that tips when filled to a calibrated level.
Note: In the illustration, the rain gage is shown with a pole, which is sold separately.
Read MoreThe "-QD" version of this product has a cable that terminates in a military style connector (instead of pigtails) and is the ideal length for attachment to a RAWS-F Fire Weather Quick Deployment Station.
对于此版本的TE525雨量,电缆具有军用连接器而不是尾纤。连接器连接到Raws-F火天气快速部署站。TE525-QD有一个6“孔口,以0.01英寸的增量测量降雨量。TE525-QD FUNNELS沉淀成填充到校准水平时提示的铲斗机制。
Sensor Type | 折叠铲斗/磁性簧片开关 |
材料 | Anodized aluminum |
Operating Temperature Range | 0°至50°C |
解决 | 1提示 |
Volume per Tip | 4.73 ml/tip (0.16 fl. oz/tip) |
每天降雨量 | 0.254 mm (0.01 in.) |
准确性 | 1.0%最多2 in./h(50 mm / h) |
电缆类型 | 2-conductor shielded |
Funnel Collector Diameter | 15.4 cm (6.06 in.) |
高度 | 24.1 cm (9.5 in.) |
Cable Length | 233.68 cm (92 in.) |
Cable Weight | 0.1 kg (0.2 lb) per 3.05 m (10 ft) length |
Tipping Bucket Weight | 0.9 kg (2.0 lb) |
The military style connector attaches to the RAWS-F Fire Weather Quick Deployment Station, which has an on-board CR1000.
Number of FAQs related toTE525-QD:5
展开全部全部收缩
信息包含在校准表differs with each sensor. For some sensors, the sheet contains coefficients necessary to program a data logger. For other sensors, the calibration sheet is a pass/fail report.
Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:
If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field in the product’s Ordering information. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.
如果电缆用特殊连接器终止用于唯一系统,则型号的末尾指定哪种系统。例如,034B-ET模型将传感器指定为ET107系统的034B。
并非每个传感器都有不同的电缆终端选项。可以通过在传感器产品页面的“排序信息”区域中查看两个位置来检查特定传感器的选项:
如果在-ET中提供传感器,-ETM,-LC,-LQ或-QD版本,则该选项的可用性反映在传感器型号中。例如,034b作为034b-et,034b-etm,034b-lc,034b-lq和034b-qd提供。
如果有可用的所有其他电缆终端选项将列在“电缆终止选项”下的传感器产品页面的“订购信息”区域上列出。例如,034B-L风装置具有-CWS,-PT和-PW选项,如034B-L产品页面的排序信息区域所示。
Note:As newer products are added to our inventory, typically, we will list multiple cable termination options under a single sensor model rather than creating multiple model numbers. For example, the HC2S3-L has a –C cable termination option for connecting it to a CS110 instead of offering an HC2S3-LC model.
This depends on the information contained in the calibration sheet:
Many Campbell Scientific sensors are available with different cable termination options. These options include the following:
Note:The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact Campbell Scientific for assistance.