RETIRED ›
This product is no longer available and has been replaced by:TE525-L.
TE525-LQ.德克萨斯州电子雨量值0.01英寸(0.254毫米)尖端6英寸孔口
Services Available

概述

TE525-LQ有一个6“孔口,以0.01英寸的增量降雨量。TE525-LQ漏斗沉淀成填充到校准水平时提示的铲斗机构。

Read More

The "-LQ" version of this product terminates in a military style connector (instead of pigtails) for use with a RAWS-P Permanent Remote Automated Weather Station. The length of the cable is specified at the time of order.


Images

Detailed Description

For this version of the TE525 Rain Gage, the cable terminates in a military style connector and has a user-specified lead length. The connector attaches to the RAWS-P enclosure, which mounts to a CM6/CM10 tripod, CM110-series tripod, or UT-series tower. The TE525-LQ has a 6" orifice and measures rainfall in 0.01 inch increments. The TE525-LQ funnels precipitation into a bucket mechanism that tips when filled to a calibrated level.

Specifications

Sensor Type 折叠铲斗/磁性簧片开关
材料 Anodized aluminum
温度 0°至50°C
解决 1提示
Volume per Tip 4.73 ml/tip (0.16 fl. oz/tip)
每天降雨量 0.254 mm (0.01 in.)
准确性 1.0%最多2 in./h(50 mm / h)
Funnel Collector Diameter 15.4 cm (6.06 in.)
电缆 2-conductor shielded
高度 24.1 cm (9.5 in.)
Tipping Bucket Weight 0.9 kg (2.0 lb)
电缆Weight 0.1 kg (0.2 lb) per 3.048-m (10-ft) length

Compatibility

传感器电缆终止于军用连接器,用于连接到Raws-P外壳。


Frequently Asked Questions

Number of FAQs related toTE525-LQ.:5

展开全部全部收缩

  1. 信息包含在校准表differs with each sensor. For some sensors, the sheet contains coefficients necessary to program a data logger. For other sensors, the calibration sheet is a pass/fail report.

  2. Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:

    • An –LC model has a user-specified cable length for connection to an ET107, CS110, or retired Metdata1.
    • An –LQ model has a user-specified cable length for connection to a RAWS-P weather station.

    If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field in the product’s Ordering information. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.

    如果电缆用特殊连接器终止用于唯一系统,则型号的末尾指定哪种系统。例如,034B-ET模型将传感器指定为ET107系统的034B。

    • -et模型与ET107气象站的连接器终止。
    • –ETM models terminate with the connector for an ET107 weather station, but they also include a special system mounting, which is often convenient when purchasing a replacement part.
    • –QD models terminate with the connector for a RAWS-F Quick Deployment Station.
    • –PW models terminate with the connector for a PWENC or pre-wired system.
  3. 并非每个传感器都有不同的电缆终端选项。可以通过在传感器产品页面的“排序信息”区域中查看两个位置来检查特定传感器的选项:

    • Model number
    • 电缆终止选项列表

    如果在-ET中提供传感器,-ETM,-LC,-LQ或-QD版本,则该选项的可用性反映在传感器型号中。例如,034b作为034b-et,034b-etm,034b-lc,034b-lq和034b-qd提供。

    如果有可用的所有其他电缆终端选项将列在“电缆终止选项”下的传感器产品页面的“订购信息”区域上列出。例如,034B-L风装置具有-CWS,-PT和-PW选项,如034B-L产品页面的排序信息区域所示。

    Note:As newer products are added to our inventory, typically, we will list multiple cable termination options under a single sensor model rather than creating multiple model numbers. For example, the HC2S3-L has a –C cable termination option for connecting it to a CS110 instead of offering an HC2S3-LC model.

  4. This depends on the information contained in the calibration sheet:

    • 如果校准表包含系数信息,Campbell Scientific会保留副本,并且可以请求替换副本。
    • 如果校准表不包含系数,则Campbell Scientific不会保留副本。可以联系原始制造商以进行替换副本。
  5. Many Campbell Scientific sensors are available with different cable termination options. These options include the following:

    • -pt(-pt w / tinned wirs)选项是默认选项,并在产品行上显示其他选项。电缆终止于直接连接到数据记录器的尾纤。
    • In the –C (–C w/ET/CS110 Connector) option, the cable terminates in a connector that attaches to a CS110 Electric Field Meter or an ET-series weather station.
    • In the –CWS (–CWS w/CWS900 Connector) option, the cable terminates in a connector that attaches to a CWS900-series interface. Connection to a CWS900-series interface allows the sensor to be used in a wireless sensor network.
    • In the –PW (–PW w/Pre-Wire Connector) option, the cable terminates in a connector that attaches to a prewired enclosure.
    • In the –RQ (–RQ w/RAWS Connector) option, the cable terminates in a connector that attaches to a RAWS-P Permanent Remote Automated Weather Station.

    Note:The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact Campbell Scientific for assistance.