Services Available | |
---|---|
Repair | Yes |
Free Support | Yes |
The SR50AT-316SS is a stainless-steel version of Campbell Scientific's acoustic sensor for measuring the distance from the sensor to a target. The stainless-steel chassis allows for operation in environments where corrosion is a concern (that is, marine). It is typically used to measure snow depth, but it is well-suited for other uses.
The SR50AT-316SS includes an external temperature sensor and outputs a temperature-corrected distance reading, eliminating the need for further post-processing. This sensor is compatible with most Campbell Scientific data loggers.
Read MoreThe SR50AT-316SS was designed to meet the stringent requirements of measuring depths and uses a multiple echo processing algorithm to help ensure measurement reliability.
SDI-12, RS-232, and RS-485 output options are available for measuring the SR50AT-316SS. Campbell Scientific’s MD485 interface can be used to connect one or more SR50AT-316SS sensors in RS-485 mode to an RS-232 device. This can be useful for sensors that require lead lengths that exceed the limits of either RS-232 or SDI-12 communications. TheSR50ATH-Lis available with a heater option for locations where rime ice is a problem.
The SR50A replaced the SR50 in March 2007. The newer SR50A is smaller and has different output options than its predecessor.
Measurement Time | < 1.0 s |
Output Options | SDI-12 version 1.3, RS-232, RS-485 (output options selected by configuring internal jumpers) |
波特率 | 1200 to 38400 bps (RS-232, RS-485 modes) |
Power Requirements | 9 to 18 Vdc (typically powered by data logger’s 12 Vdc power supply) |
Measurement Range | 0.5 10米(1.6到32.8ft) |
Beam Acceptance | ~30° |
Resolution | 0.25 mm (0.01 in.) |
Accuracy | ±1 cm (0.4 in.) or 0.4% of distance to target (whichever is greatest). Requires external temperature compensation. |
Operating Temperature Range | -45° to +50°C |
Compliance | CE Compliant |
Temperature Accuracy |
|
Diameter | 7.5 cm (3 in.) |
Length | 10.1 cm (4.0 in.) |
Weight | 795 g (28 oz) without cable |
Cable Weight | 250 g (8.2 oz) for a 4.57-m (15-ft) cable |
Power Consumption |
|
Active | 250 mA (typical) |
Quiescent SDI-12 Mode | < 1.0 mA |
Quiescent RS-232/RS-485 Modes |
|
Maximum Cable Length |
|
-NOTE- | Cable lengths greater than 60 m require a heavier gage wire if the power supply drops below 11 Vdc. |
SDI-12 | 60 m (200 ft) |
RS-232 | 60 m (200 ft) Baud rates ≤ 9600 bps |
RS-485 | 300 m (984 ft) |
Note:The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.
Product | Compatible | Note |
---|---|---|
21X(retired) | SDI-12 | |
CR10(retired) | SDI-12 | |
CR1000(retired) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR1000X | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR10X(retired) | SDI-12 | |
CR200X(retired) | SDI-12 | |
CR206X(retired) | SDI-12 | |
CR211X(retired) | SDI-12 | |
CR216X(retired) | SDI-12 | |
CR23X(retired) | SDI-12 | |
CR295X(retired) | SDI-12 | |
CR300 | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR3000(retired) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR310 | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR500(retired) | SDI-12 | |
CR5000(retired) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR510(retired) | SDI-12 | |
CR6 | SDI-12, RS-232, and RS-485 | |
CR800 | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR850 | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. | |
CR9000(retired) | ||
CR9000X(retired) | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. |
Product | Compatible | Note |
---|---|---|
GRANITE 6 | SDI-12 and RS-232. For RS-485, requires an MD485 interface or similar RS-485 to RS-232 interface. |
One single-ended channel per probe is required; an excitation channel can be shared by several probes.
We've updated our privacy policy.Learn More