Short Cut Program Generator for Windows (SCWin)
Eases Programming
Simple way to generate data logger programs
weather applications water applications energy applications gas flux and turbulence applications infrastructure applications soil applications

Overview

Current Version: 4.4

Short Cut Program Generator (SCWin) is a free, menu-driven, PC-compatible software package that simplifies the creation of data logger programs; it creates a data logger program in seven easy steps.

To download Short Cut, refer to the Downloads section or click the Download Now button.

Read More

Benefits and Features

  • Creates a data logger program in seven easy steps.
  • Generates a printable wiring diagram.
  • Supports both standard sensors and generic measurements (e.g., bridge, pulse).
  • Supports the AM25T, AM16/32B, AM16/32A, AM16/32, AM416, and AM32 multiplexers.
  • Supports CDM and GRANITE VOLT Analog Input Modules.
  • Supports GRANITE TEMP Thermocouple Modules.
  • Supports the AVW200 2-Channel Vibrating-Wire Analyzer Module.
  • Supports ET106, ET107, and MetData1 Weather Stations.
  • Includes a reference crop evapotranspiration calculation module and other mathematical calculations.
  • Can be downloaded free of charge; see Downloads section or Download Now button on web page.

Images

Detailed Description

Originally intended to support meteorological and hydrological applications, the initial releases of Short Cut (SCWin) supported over 120 sensors. Now, with additional program generation capabilities, Short Cut supports programming for our multiplexers, AVW200-series Vibrating-Wire Interfaces, ET107 stations, ET106 stations, MetData1 stations, and most sensors that can be measured by our data loggers.

Short Cut allows the user to select sensors and choose output data. Short Cut then creates a wiring diagram and a program file for transfer to the data logger. It also includes support for algebraic entry of expressions.

Specifications

Current Version 4.4
Operating System Windows 11, 10, 8, and 7 (Both 32- and 64-bit operating systems are supported.)
Requirement .NET 4.0
Purchased Separately Free download
Software Level Entry
Communications Supported N/A (program generator only)
Scheduled Data Collection Supported N/A (program generator only)
Data Display Supported N/A (program generator only)

Compatibility

Note:The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Data Loggers

Product Compatible Note
21X(retired)
CR10(retired)
CR1000(retired)
CR1000X
CR10X(retired)
CR200X(retired)
CR206X(retired)
CR211X(retired)
CR216X(retired)
CR23X(retired)
CR295X(retired)
CR300
CR3000
CR310
CR500(retired)
CR5000(retired)
CR510(retired)
CR6
CR800
CR850
CR9000(retired)
CR9000X(retired)

Distributed Data Acquisition

Product Compatible Note
GRANITE 10
GRANITE 6
GRANITE 9

Additional Compatibility Information

Computer Requirements

Computer operating systems—Windows 7, 8, 10, and 11. Short Cut runs on both 32-bit and 64-bit versions of these operating systems.

产品支持

Short Cut supports more than 100 sensors (including generic measurements), multiplexers, AVW200-series vibrating-wire interfaces, and the ET107.

Documents

Brochures


Downloads

Short Cut v.4.4 (29.3 MB)03-16-2021

Short Cut creates simple programs for our CR200-series, CR300-series, CR510, CR500, CR10(X), 21X, CR23X, CR6, CR800, CR1000(X), CR3000, CR5000, CR9000X and GRANITE dataloggers. Both mixed array and table data operating systems are supported. Short Cut also supports our ET106, ET107 and MetData1 weather stations. The newest version includes the latest sensor files.

View Update History

Frequently Asked Questions

Number of FAQs related toShort Cut:15

Expand AllCollapse All

  1. TheSCWinrevision history information can be found through the “Software and OS Revision Histories” web page forShort Cut.

  2. No. A CRBasic or Edlog data logger editor (included inPC400andLoggerNetsoftware) is needed to write program code for the TDR100.Short Cut for Windows(SCWin) is not designed to handle the many variables of the TDR100.

  3. Yes. In the|Level & Flowfolder, there is the option to selectCS475/CS476/CS477 Radar Water Level Sensor. Click to move the selection to theSelected井斜ce window, and enter the SDI-12 address.

  4. Short Cut does not allow mV readings. To record the raw mV data before it is converted to NTU, open the Short Cut file in the CRBasic Editor, and alter the program manually.

  5. It is possible that an older version ofShort Cutis being used. Download thelatest version ofShort Cut.

    For programming assistance, consult theNR01-L说明书. For additional assistance, contact Campbell Scientific.

  6. TheHalf Bridgeinstruction should be selected (not the 3 Wire or 4 Wire options) inShort Cut. The following parameters are data logger specific, but the following can be used on the CR1000 datalogger with the sensor wired to SE1, and Vx1:

    How many HalfBr Sensors? 1
    Total Bridge Resistance 1000 ohm
    Excitation Voltage 2500 mV
    Sensors per excitation channel 1
    Range of sensor voltage 2500 mV
    Reverse Excitation Yes
    Measurement Integration

    50 or 60Hz

    Settling Time 20000µs
    Multiplier Determined during installation (see manual)
    Offset Determined during installation (see manual)
  7. We do not offer an individual manual forSCWin(Short Cut for Windows).Short Cutinformation is provided in theLoggerNet,RTDAQ, andPC400manuals. Information can also be obtained from theHelpscreens withinSCWin.

  8. A free program generator for all Campbell Scientific data loggers isShort Cut for Windows(SCWin).Short Cutcan be used to create programs in many situations where Campbell Scientific equipment is used. The Campbell Scientific YouTube channel has atwo-part series on usingShort Cut.

    In situations where program requirements are too complex or specialized forShort Cut, programs can be written in any text editor that can edit and save plain ASCII text. However, creating an error-free program would be very difficult. The CRBasic Editor that comes withPC400andLoggerNetprovides a programming environment with procedure templates, integrated help, programming examples, the ability to test compile the program before sending it, and many other features that can be very helpful when developing a program.

  9. The easiest way to program a data logger is to useSCWin(Short Cut for Windows).SCWinis available as a free download in the Downloads section of theSCWinproduct page.SCWinassigns the physical channels (connect the sensors according to the wiring diagram provided) and writes the program using the appropriate instructions and instruction parameters for the sensors selected by the user.

  10. No.Short Cutversion 3.0 cannot be used to program the data logger to send data via FTP.


Articles and Press Releases

Blog Articles

Newsletter Articles

Privacy Policy Update

We've updated our privacy policy.Learn More

Baidu