SC105是用于RS-232适配器的CS I / O,用于将CampBell Scientific Logger连接到RS-232 DCE设备。与SC105一起使用的常见DCE设备包括蜂窝调制解调器,无线电和智能串行传感器。SC105与具有CS I / O端口的任何数据记录器兼容。多个SC105接口可以连接到单个数据记录器CS I / O端口。
Read MoreThe SC105 provides internal buffering that temporarily stores data. This buffering allows the data logger and DCE device to operate at different baud rates by storing the data received from the faster device until the slower device is ready to receive it. Internal buffering also ensures that no data is lost during transmission.
支持波特率 | 1200, 9600, 19200, 38400, 57600, 115200 bps |
RS-232 Parity Supported | 偶数,没有 |
支持RS-232数据位 | 7,8 |
CS I / O端口模式 | CSDC,SDC,ME,P96输出的寻址打印设备 |
电源要求 | Data logger’s 5 V supply |
当前的流失 |
|
Operating Temperature Range |
|
操作相对湿度 | 高达95%(非凝结) |
Dimensions | 2.3 x 4.3 x 9.2 cm (0.9 x 1.7 x 3.6 in.) |
Weight | 45.4 g (1.6 oz) |
Note:以下显示了显着的兼容性信息。它不是所有兼容或不兼容产品的全面列表。
Product | Compatible | Note |
---|---|---|
21X.(retired) | 21x不支持直接输出到打印机;为此目的使用SC932。 | |
CR10(retired) | ||
CR1000.(retired) | ||
CR10X(retired) | ||
CR200x.(retired) | ||
CR206X(retired) | ||
CR211x.(retired) | ||
CR216X(retired) | ||
CR23X(retired) | ||
CR295X(retired) | ||
CR3000 | ||
CR500.(retired) | ||
CR500.0(retired) | ||
CR510(retired) | ||
CR6. | ||
CR800 | ||
CR850. | ||
CR9000(retired) | ||
CR9000x.(retired) |
SC105附带三根电缆(13657个空调制解调器电缆,SC12 CS I / O数据电缆和10873个串行数据电缆)。13657电缆用于通过计算机编程设备。SC12电缆将SC105连接到数据记录器,10873个电缆将SC105连接到RS-232 DCE器件。如果需要更长的电缆,可以使用SC12R-6电缆(单独购买)代替SC12电缆。
16987安装套件可用于将SC105安装到环境外壳的背板上。
Note:使用SC105与OS版本4或具有混合阵列数据记录器的新版本时,应将数据记录器操作系统更新为最新发布的版本。
用于下载操作系统并设置Campbell Scientific硬件的软件实用程序。如果以前由另一个Campbell Scientific软件包安装,还将更新Pakbus图表和网络规划员。
支持的操作系统:
Windows 10, 8.1, 8, and 7 (Both 32 and 64 bit)
Number of FAQs related toSC105:9
展开全部全部收缩
The SC105 uses the RS-232 standard, which is not compatible with multidrop communications (more than two devices on the same RS-232 bus). There are some third-party devices on the market that allow multiple devices to communicate over the same RS-232 link.
是的,如果PDA有RS-232端口。
Depending on what equipment is being used, a special interface may be required to attach a specific device to the data logger’s CS I/O port. In general, devices with a CS I/O port can be attached directly to the data logger’s CS I/O port. Devices with an RS-232 port require a special interface, such as theSC932A要么SC105, to connect to the data logger’s CS I/O port.
Both the computer’s serial port and the SC105’s RS-232 port are configured as data terminal equipment (DTE) devices. Because both components are DTE, a null modem cable is needed between them.
SC105需要直接或包含在内的数据记录器的CS I / O端口SC12cable. The SC105’s RS-232 port needs to be connected to the PC’s serial port using the included null modem cable.
Using an SC105 with a RavenXTV or RavenXTG cellular modem allows for the two devices to communicate at differing baud rates. It also allows for other devices, such as an RF401 radio or CR1000KD handheld display, to simultaneously be connected to the data logger’s CS I/O port.
SC932A仅兼容数据记录器和调制解调器之间的调制解调器(ME)双向通信。相反,SC105与ME和用于通信(SDC)通信的同步设备兼容,以及具有内部缓冲数据的能力。
An RS-232 device cannot be directly connected to the CS I/O port of the data logger. A peripheral, such as an SC932A or SC105, is required.
Most third-party modems require a null modem cable, SC105, SC110 cable, or SC932A to interface with a data logger. Many modems manufactured by Campbell Scientific can connect directly to a data logger’s CS I/O port using anSC12或串行电缆。
We've updated our privacy policy.Learn More