串行通讯/ SC105.
SC105 CS I/O to 9-Pin RS-232 DCE Synchronous Interface
沟通支持
天气应用程序 水应用 能源应用 气体通量和湍流应用 infrastructure applications soil applications

Overview

SC105是用于RS-232适配器的CS I / O,用于将CampBell Scientific Logger连接到RS-232 DCE设备。与SC105一起使用的常见DCE设备包括蜂窝调制解调器,无线电和智能串行传感器。SC105与具有CS I / O端口的任何数据记录器兼容。多个SC105接口可以连接到单个数据记录器CS I / O端口。

Read More

Benefits and Features

  • 支持数据记录器和RS-232 DCE设备之间的通信
  • Communicates at baud rates up to 115.2 kbps
  • Provides internal buffering capability to ensure no data is lost during transmission
  • Data logger can operate at a different baud rate than the DCE device
  • No power source needed—powered by the datalogger and computer
  • 与大多数坎贝尔科学数据记录器兼容
  • Helps protect components from electrical damage
  • Ships with cables needed for most uses

Images

Detailed Description

The SC105 provides internal buffering that temporarily stores data. This buffering allows the data logger and DCE device to operate at different baud rates by storing the data received from the faster device until the slower device is ready to receive it. Internal buffering also ensures that no data is lost during transmission.

Specifications

支持波特率 1200, 9600, 19200, 38400, 57600, 115200 bps
RS-232 Parity Supported 偶数,没有
支持RS-232数据位 7,8
CS I / O端口模式 CSDC,SDC,ME,P96输出的寻址打印设备
电源要求 Data logger’s 5 V supply
当前的流失
  • Up to 8 mA of additional current may be used by the DCE device connected to the SC105.
  • 0.16 mA (standby)
  • 1 to 4 mA (communicating)
Operating Temperature Range
  • -25°至+50ºC(标准)
  • -55° to +85°C (extended)
操作相对湿度 高达95%(非凝结)
Dimensions 2.3 x 4.3 x 9.2 cm (0.9 x 1.7 x 3.6 in.)
Weight 45.4 g (1.6 oz)

Compatibility

Note:以下显示了显着的兼容性信息。它不是所有兼容或不兼容产品的全面列表。

Data Loggers

Product Compatible Note
21X.(retired) 21x不支持直接输出到打印机;为此目的使用SC932。
CR10(retired)
CR1000.(retired)
CR10X(retired)
CR200x.(retired)
CR206X(retired)
CR211x.(retired)
CR216X(retired)
CR23X(retired)
CR295X(retired)
CR3000
CR500.(retired)
CR500.0(retired)
CR510(retired)
CR6.
CR800
CR850.
CR9000(retired)
CR9000x.(retired)

额外的兼容性信息

Cable Connections and Mounts

SC105附带三根电缆(13657个空调制解调器电缆,SC12 CS I / O数据电缆和10873个串行数据电缆)。13657电缆用于通过计算机编程设备。SC12电缆将SC105连接到数据记录器,10873个电缆将SC105连接到RS-232 DCE器件。如果需要更长的电缆,可以使用SC12R-6电缆(单独购买)代替SC12电缆。

16987安装套件可用于将SC105安装到环境外壳的背板上。

数据记录器考虑因素

Note:使用SC105与OS版本4或具有混合阵列数据记录器的新版本时,应将数据记录器操作系统更新为最新发布的版本。

下载

SC105 OS v.04(573 KB)08-28-2007

Current SC105 firmware. Requires the Device Configuration Utility and a 9-pin female to female NULL modem cable.
查看更新历史记录

Device Configuration Utility v.2.26 (44.8 MB)03-16-2021

用于下载操作系统并设置Campbell Scientific硬件的软件实用程序。如果以前由另一个Campbell Scientific软件包安装,还将更新Pakbus图表和网络规划员。

支持的操作系统:

Windows 10, 8.1, 8, and 7 (Both 32 and 64 bit)

查看更新历史记录

Frequently Asked Questions

Number of FAQs related toSC105:9

展开全部全部收缩

  1. The SC105 uses the RS-232 standard, which is not compatible with multidrop communications (more than two devices on the same RS-232 bus). There are some third-party devices on the market that allow multiple devices to communicate over the same RS-232 link.

  2. 是的,如果PDA有RS-232端口。

  3. Depending on what equipment is being used, a special interface may be required to attach a specific device to the data logger’s CS I/O port. In general, devices with a CS I/O port can be attached directly to the data logger’s CS I/O port. Devices with an RS-232 port require a special interface, such as theSC932A要么SC105, to connect to the data logger’s CS I/O port.

  4. Both the computer’s serial port and the SC105’s RS-232 port are configured as data terminal equipment (DTE) devices. Because both components are DTE, a null modem cable is needed between them.

  5. SC105需要直接或包含在内的数据记录器的CS I / O端口SC12cable. The SC105’s RS-232 port needs to be connected to the PC’s serial port using the included null modem cable.

  6. Using an SC105 with a RavenXTV or RavenXTG cellular modem allows for the two devices to communicate at differing baud rates. It also allows for other devices, such as an RF401 radio or CR1000KD handheld display, to simultaneously be connected to the data logger’s CS I/O port.

  7. SC932A仅兼容数据记录器和调制解调器之间的调制解调器(ME)双向通信。相反,SC105与ME和用于通信(SDC)通信的同步设备兼容,以及具有内部缓冲数据的能力。

  8. An RS-232 device cannot be directly connected to the CS I/O port of the data logger. A peripheral, such as an SC932A or SC105, is required.

  9. Most third-party modems require a null modem cable, SC105, SC110 cable, or SC932A to interface with a data logger. Many modems manufactured by Campbell Scientific can connect directly to a data logger’s CS I/O port using anSC12或串行电缆。

Case Studies

south korea: damage from freezing roads
韩国:冻结道路的损坏
韩国高速公路公司(KEC)于1969年成立,建设和管理南方的高速公路......阅读更多

隐私政策更新

We've updated our privacy policy.Learn More

Baidu