Services Available | |
---|---|
Repair | Yes |
免费支持 | Yes |
The RF500M is a versatile radio modem for networks with UHF/VHF radios, typically serving as an interface between the data logger and radio. In addition to serving as a field modem connected to a data logger, the RF500M can also be used as a stand-alone repeater, or as a base-station modem connected to a computer. The RF500M is generally used with legacy or existing PakBus and mixed-array/dial-up networks. The RF500M works with our RF320-series radios, RF310-series radios, RF300-series radios, or any radio and modem combination that outputs a demodulated byte stream via RS-232.
For new installations, please consider one of ourspread-spectrum radio solutions, or contact Campbell Scientific to discuss the use of other licensed radio options.
The RF500M is an appropriate choice for any ALERT(1) store-and-forward repeaters or base-station-decoder applications. For ALERT2 applications, refer to theAlert200 Alert2基本远程数据平台.
Read MoreRF500M通常用于远程,中继器和基站通信接口,通常用于我们的许可无线电应用程序。它在数据记录器或计算机和无线电之间提供了一个接口,并且在不需要现场记录时,可以是独立的中继器。RF500M从CS I / O端口或外部电源连接供电。该调制解调器是可配置的软件,并设计为与数据遥测无线电接口,如我们的RF320-,RF310-和RF300系列VHF / UHF无线电。
考虑了RF500M的标准,-PB OS使用TDRF轮询来快速和有效地通过网络移动数据。每个站都可以通过LogGernet单独拨打。此操作系统与-TD,-PB和我们当前的Pakbus数据记录器的生成兼容。
The ALERT (Automated Local Evaluation in Real Time) OS allows for transmission, repeating, and reception of binary ALERT formatted data. It is a derivative of the -PB OS, and therefore supports both ALERT and TDRF communications (allowing true two-way communication with a station). This OS is compatible with the CR200(X)-series, CR800-series, CR1000, and CR3000 dataloggers.
拨号操作系统适用于混合阵列and PakBus/table-based data loggers. Each station can be dialed by LoggerNet for downloading data, sending programs, and performing other tasks. Additionally, this OS allows stations to create point-to-point networks for sharing of measurement and control tasks.
Voltage | 7到20 VDC(可以由CS I / O端口提供。) |
Active Current Drain | < 8 mA RMS (@ 12 Vdc) |
Temperature Response | -25° to +50°C (standard) |
温度范围 | -55° to +85°C (extended) |
Dimensions | 16.0 x 9.5 x 2.2 cm (6.31 x 3.69 x 0.88 in.) |
Weight | 0.18 kg (0.4 lb) |
收发器音频输出(引脚5) |
|
J1 Jumper Configuration | 310 mV peak-to-peak (Campbell Scientific adjusts the audio input gain so that it is compatible with J1.) |
J3跳线配置 | 670 mV peak-to-peak |
Time division polling and PakBus communications can be used in the same network as long as all of the data loggers are PakBus versions.
RF500M OS. | CR200(X) Series | CR800 / CR850 |
CR1000 | CR3000 | CR6 | CR9000X | CR300系列 |
-PB | # | ** | # | ||||
-da. | |||||||
- - |
RF500M OS. | CR 500. |
CR 510. |
CR 10 |
CR 10T |
CR 10X |
21X | CR 23X |
CR 9000 |
CR 500.0 |
CR 7x. |
-PB | ‡ | ‡ | ‡ | |||||||
-da. | ♣ | ♣ | ♣ | |||||||
- - |
Notes:
#The RF500M cannot be a repeater while the modem is connected to a CR200(X) or CR300-series datalogger.
**The RF500M is only compatible with the CR6 when using -PB OS version 3 or later.
‡The -PB OS option for the RF500M is only compatible with the-PB and -TDCR510,CR10x和CR23x的操作系统.
♣RF500M - da系统的选择是不兼容的with the -TD OS option for the CR510, CR10X, and CR23X.
Three jumper settings allow the RF500M to be used with a variety of radios. Though not a requirement, it is a good idea to standardize your network to use a single radio type. This practice simplifies operations and maintenance and provides the highest degree of interstation compatibility possible.
RF320 Series | RF310系列 | RF300 Series | Calamp dataradio DL-3400. |
Digital/ RS-232 Radio |
RF200 | RF100. |
† |
Note:
†The RF500M must have the -PB OS option to use a digital RS-232 radio with it.
Networks can contain a mixture of RF500M modems and other Campbell Scientific radio modems and base stations assuming they have compatible operating systems (see chart below).
Modem/ Base Station |
-PB OS. | -da OS. | - OS | |
RF500M | -PB | * | ||
-da. | ||||
- - | ||||
RF500B | -PB | * | ||
-da. | ||||
- - | ||||
RF310M | -TD. | * | ||
-MA | ||||
- - | ||||
RF310B. | -TD. | * | ||
-MA | ||||
- - | ||||
RF315M | -TD. | * | ||
-MA | ||||
- - | ||||
rf95a. | -TD. | * | ||
-MA | ||||
- - | ||||
rf232a. | -TD. | * | ||
-MA | ||||
- - |
Notes:
*利用TDRF和双向通信时。
Execution of this download copies the ALERT Operating System (-AL) for the RF500M onto your computer. The ALERT (Automated Local Evaluation in Real Time) OS allows for transmission, repeating, and reception of binary ALERT formatted data. This OS is compatible with the CR200(X) series, CR800 series, CR1000, and CR3000.
Note: Requires Device Configuration Utility 2.01 or newer.
执行此下载复制拨号操作系统(-da)
RF500M到您的计算机上。拨号操作系统适用于混合阵列
and PakBus/Table based loggers with the exception of the CR200(X);
only the CS I/O port of the modem is used for data transfer. Each
station can be a point-to-point node and repeater and can be dialed by
用于数据传输和远程管理的Loggernet。
Note: Requires Device Configuration Utility 2.01 or newer.
执行此下载将Pakbus操作系统(-PB)复制到计算机上的RF500M。-PB OS使用TD-RF轮询来快速和有效地通过网络移动数据。此外,每个站可以通过LogGernet单独拨打。此操作系统与-TD,-PB和我们当前的Pakbus DataLoggers兼容。
Note: Requires Device Configuration Utility 2.01 or newer.
Number of FAQs related toRF500M:7
Expand AllCollapse All
不可以.RF500M不能直接与GPS接收器接口。然而,大多数坎贝尔科学数据记录器可以与GPS接收器的输出接口,并编程以提取位置信息。然后可以通过RF500M / RF320 RF链路访问此信息。
Usually, yes. Contact Campbell Scientific for a return material authorization number (RMA) and instructions for returning the unit for repair. Additional information is available on theRepair and Calibration页。
不可以.CR1000KD专门用于CR800,CR1000和CR6 DataLoggers的CS I / O端口。
通常,工程图形不是公众可以访问。有关特定问题,请联系Campbell Scientific获得帮助。
如果RF调制解调器具有CS I / O连接器,则应与CR10x兼容而不使用SC932a。确保RF调制解调器的固件与CR10x固件兼容。
Note:RF modems that are not sold by Campbell Scientific will only interface with a CR10X via an SC932A or an SC105.
We've updated our privacy policy.Learn More