092-L Barometer
Suitable for Wind-Farm Power Performance Measurements
weather applications water applications energy applications gas flux and turbulence applications infrastructure applications soil applications

Overview

The 092, manufactured by Met One, is a barometric pressure sensor that is commonly used with the WMS100 for wind-farm power performance measurements. It has a polycarbonate casing and a metal weather shield, so it is rugged and weatherproof. You can use it indoors or outdoors, and it provides digital and analog outputs.

Images

Specifications

Measurement Description Barometric pressure
Signal Type/Output Analog voltage
-NOTE- 1 hPa = 1 mBar
Pressure Range 600 to 1100 hPa
Elevation Sea level to 3048 m (10,000 ft)
Resolution 0.1 hPa
Long-Term Stability ±1.0 hPa in 1 year
Analog Output 0 to 1 Vdc, 0 to 2 Vdc, 0 to 2.5 Vdc, or 0 to 5 Vdc (Analog output automatically adjusts from zero to full scale for range selected.)
Digital Output RS-232, RS-485, and SDI-12
Digital Protocol ASCII Terminal Mode, RTU for RS-232 and RS-485
Baud Rates 1200, 2400, 4800, 9600, 19.2k bps
Current Consumption 10 mA @ 12 Vdc (typical)
Power Range 6 to 16 Vdc
Temperature Range -40° to +55°C
Elevation ~609.6 m (2,000 ft) below sea level (as in a mine) to 3,657.6 m (12,000 ft) above sea level
Accuracy
  • ±0.35 hPa (@ 20°C)
  • ±1.0 hPa (±0.03 in Hg) over full range
  • ±0.5 hPa (over any 200 hPa range)
Dimensions 12.0 x 8.0 x 5.5 cm (4.72 x 3.14 x 2.16 in.)
Weight 250 g (8.8 oz)

Compatibility

Note:The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Data Loggers

Product Compatible Note
CR1000(retired)
CR1000X
CR200X(retired)
CR206X(retired)
CR211X(retired)
CR216X(retired)
CR300
CR3000(retired)
CR310
CR350
CR5000(retired)
CR6
CR800
CR850
CR9000X(retired)

Additional Compatibility Information

Mounting

The 092 includes in a small polycarbonate enclosure with metal weather shield. It may be mounted outside or inside a building

Documents


Frequently Asked Questions

Number of FAQs related to092-L:3

Expand AllCollapse All

  1. Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:

    • An –LC model has a user-specified cable length for connection to an ET107, CS110, or retired Metdata1.
    • An –LQ model has a user-specified cable length for connection to a RAWS-P weather station.

    If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field in the product’s Ordering information. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.

    If a cable terminates with a special connector for a unique system, the end of the model number designates which system. For example, the 034B-ET model designates the sensor as a 034B for an ET107 system.

    • –ET models terminate with the connector for an ET107 weather station.
    • –ETM models terminate with the connector for an ET107 weather station, but they also include a special system mounting, which is often convenient when purchasing a replacement part.
    • –QD models terminate with the connector for a RAWS-F Quick Deployment Station.
    • –PW models terminate with the connector for a PWENC or pre-wired system.
  2. Not every sensor has different cable termination options. The options available for a particular sensor can be checked by looking in two places in the Ordering information area of the sensor product page:

    • Model number
    • Cable Termination Options list

    If a sensor is offered in an –ET, –ETM, –LC, –LQ, or –QD version, that option’s availability is reflected in the sensor model number. For example, the 034B is offered as the 034B-ET, 034B-ETM, 034B-LC, 034B-LQ, and 034B-QD.

    All of the other cable termination options, if available, are listed on the Ordering information area of the sensor product page under “Cable Termination Options.” For example, the 034B-L Wind Set is offered with the –CWS, –PT, and –PW options, as shown in the Ordering information area of the 034B-L product page.

    Note:As newer products are added to our inventory, typically, we will list multiple cable termination options under a single sensor model rather than creating multiple model numbers. For example, the HC2S3-L has a –C cable termination option for connecting it to a CS110 instead of offering an HC2S3-LC model.

  3. Many Campbell Scientific sensors are available with different cable termination options. These options include the following:

    • pt (pt w /镀锡线)选项是默认的option and does not display on the product line as the other options do. The cable terminates in pigtails that connect directly to a data logger.
    • - c (- c w / ET / CS110连接器)选项,cable terminates in a connector that attaches to a CS110 Electric Field Meter or an ET-series weather station.
    • In the –CWS (–CWS w/CWS900 Connector) option, the cable terminates in a connector that attaches to a CWS900-series interface. Connection to a CWS900-series interface allows the sensor to be used in a wireless sensor network.
    • In the –PW (–PW w/Pre-Wire Connector) option, the cable terminates in a connector that attaches to a prewired enclosure.
    • In the –RQ (–RQ w/RAWS Connector) option, the cable terminates in a connector that attaches to a RAWS-P Permanent Remote Automated Weather Station.

    Note:The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact Campbell Scientific for assistance.