的HMP155A provides reliable relative humidity (RH) and temperature measurements for a wide range of applications. It uses a HUMICAP®180R电容薄膜聚合物传感器可在0至100%RH范围内测量RH。PRT测量在-80°至 +60°C范围内的温度。这种坚固,准确的温度/RH探针由Vaisala制造。
Read More的"-L" on a product model indicates that the cable length is specified at the time of order.
To reduce the current drain, power can be supplied to the HMP155A only during measurement when the sensor is connected to the data logger’s switched 12 V terminal. Data loggers that do not have a switched 12 V terminal, such as the CR510 or CR7, can use the SW12V switched 12 V device to switch power to the sensor only during measurement.
Electromagnetic Compatibility | 符合EMC标准EN61326-1电磁 |
过滤器描述 | Sintered PTFE |
Housing Body Material | 个人电脑 |
住房分类 | IP66 |
电压输出 | 0到1 VDC |
Average Current Consumption | ≤ 3 mA (analog output mode) |
工作电压 | 7 to 28 Vdc |
安顿时间 | 2 s (at power up) |
可获得的芯片或重新校准 | 重新校准 |
Tip Diameter | 1.2 cm (0.5 in.) |
Length | 27.9厘米(11英寸) |
头高 | 4厘米(1.6英寸) |
身高 | 2.4厘米(0.9英寸) |
身体宽度 | 2.0 cm (0.8 in.) |
Relative Humidity |
|
Sensing Element | 腐殖质180r |
测量范围 | 0至100%rh(非调节) |
响应时间 |
|
工厂校准不确定性 |
|
准确性 |
|
Air Temperature |
|
Sensing Element | PT 100 RTD 1/3 B级IEC 751 |
测量范围 | -80°至 +60°C |
准确性 |
|
整个温度范围 | Refer to graph in probe manual. |
Note:以下显示了显着的兼容性信息。这不是所有兼容或不兼容产品的全面列表。
Product | Compatible | Note |
---|---|---|
21x(retired) | ||
CR10(retired) | ||
CR1000(retired) | ||
CR1000X | ||
CR10X(retired) | ||
CR200X(retired) | ||
CR206X(retired) | ||
CR211X(retired) | ||
CR216X(retired) | ||
CR23X(retired) | ||
CR295X(retired) | ||
CR300 | ||
CR3000(retired) | ||
CR310 | ||
CR500(retired) | ||
CR5000(retired) | ||
CR510(retired) | ||
CR6 | ||
CR800 | ||
CR850 | ||
CR9000(retired) | ||
CR9000X(retired) | ||
CR9000XC(retired) |
当暴露于阳光下时,HMP155A必须放置在41005-5或RAD14 14板自然吸气辐射屏蔽层中。41005-5和RAD14连接到具有2.5至5.3 cm(1.0至2.1英寸)外径的交叉臂,桅杆或用户供应管。RAD14使用双层设计,可改善传感器保护,以防止雨水,雪和昆虫入侵,它在明亮的阳光下也具有较低的自热性,并结合了较高的温度(> 24°C [〜75°F])
和低风速(<2 m s-1[〜4.5 mph]),给出更好的测量。
描述:示例CR1000X程序,测量HMP155A的模拟电压或RS-485输出。模拟电压程序使用Voltse或Voltdiff指令,并仅在测量过程中将电源切换到传感器。一个程序还计算平均蒸气压。RS-485程序用SDM-SIO1A/SIO4A测量RS-485输出。尽管这些程序是为CR1000X编写的,但其他数据量的程序将相似。
Number of FAQs related toHMP155A-L:7
展开全部全部收缩
最大电缆长度为304 m(1000 ft)。
No. The HMP155A-L requires the41005-514-Plate Solar Radiation Shield.
Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:
If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field in the product’s Ordering information. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.
如果电缆用特殊的连接器终止于唯一系统,则型号的末端指定了哪个系统。例如,034B-ET模型将传感器指定为ET107系统的034B。
并非每个传感器都有不同的电缆终止选项。可以通过在传感器产品页面的订购信息区域的两个地方查看特定传感器的选项:
如果在–ET,–ETM,–LC,–LQ或–QD版本中提供传感器,则该选项的可用性反映在传感器型号中。例如,034b以034b-et,034b-etm,034b-lc,034b-LQ和034b-qD提供。
如果有的话,所有其他电缆终止选项均在传感器产品页面的“电缆终止选项”下的“订购信息”页面上列出。例如,如034B-L产品页面的订购信息区域所示,使用–CWS,–PT和–PW选项提供034B-L风集。
Note:As newer products are added to our inventory, typically, we will list multiple cable termination options under a single sensor model rather than creating multiple model numbers. For example, the HC2S3-L has a –C cable termination option for connecting it to a CS110 instead of offering an HC2S3-LC model.
Note the difference between calibration and a field check. Calibration cannot be done in the field, as it requires an experienced technician and specialized equipment.
Field checks of measurements can be done to determine if the data make sense with the real-world conditions. Follow these steps to field check a sensor:
Many Campbell Scientific sensors are available with different cable termination options. These options include the following:
Note:的availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact Campbell Scientific for assistance.
Single-ended channels are typically used when it is desirable to use fewer channels and the cable length is shorter—less than 6.1 m (20 ft). Differential channels are preferable when the cable needs to be longer than 6.1 m (20 ft).