Tips and troubleshooting

Start with these basic procedures if a system is not operating properly.

  1. Ensure your system is well grounded. SeeGrounds. The symptoms of a poorly grounded system range from bad measurements, to intermittent communications, to damaged hardware.

  2. 使用电压表,检查沃尔特ge of the primary power source at the POWER IN terminals on the face of the data logger, it should be 10 to 18 VDC.

  3. Check wires and cables for the following:

  4. Check theClosedCRBasicCampbell Scientific's BASIC-like programming language that supports analog and digital measurements, data processing and analysis routines, hardware control, and many communications protocols.program. If the program was written solely withClosedShort CutA CRBasic programming wizard suitable for many data logger applications. Knowledge of CRBasic is not required to use Short Cut., the program is probably not the source of the problem. If the program was written or edited withClosedCRBasicEditorThe CRBasic programming editor; stand-alone software and also included with LoggerNet, PC400, and RTDAQ software., logic and syntax errors could easily have crept in. To troubleshoot, create a simpler version of the program, or break it up into multiple smaller units to test individually. For example, if a sensor signal-to-data conversion is faulty, create a program that only measures that sensor and stores the data, absent from all other inputs and data.

  5. Reset the data logger. Sometimes the easiest way to resolve a problem is by resetting the data logger (seeResetting the data loggerfor more information).

For additional troubleshooting options, see:

Also, consider checking, or posting your question to, the Campbell Scientific user forum//www.ocbeachreo.com/forum. Our web sitewww.ocbeachreo.comhas additional manuals (with example programs), FAQs, specifications and compatibility information for all of our products.

Video tutorialswww.ocbeachreo.com/videosand blog articleswww.ocbeachreo.com/blogare also useful troubleshooting resources.