FW3 Type E Fine-Wire Thermocouple with 0.003 in. Diameter
Research Grade
High accuracy for temperature-gradient and eddy-covariance applications
weather applications water applications energy applications gas flux and turbulence applications infrastructure applications soil applications

概述

The FW3 is a Type E thermocouple with a 0.003 in. diameter. It measures atmospheric temperature gradients or fluctuations with research-grade accuracy. The FW3 is compatible with most Campbell Scientific data loggers, and it is often used in eddy-covariance systems.

Read More

Benefits and Features

  • High frequency response suitable for eddy-covariance applications
  • Extremely small diameter virtually eliminates solar loading
  • Well-suited for temperature gradient measurements

The FW/ENC Carrying Case is required to ship our FW3 thermocouples. It holds up to four thermocouples.


Images

Detailed Description

The FW3's small mass eliminates the need for a solar radiation shield. It consists of a type E thermocouple with a connector. The connector attaches the thermocouple to a data logger via the FWC-L cable.

Type E thermocouples are comprised of a chromel wire and a constantan wire joined at a measurement junction. A voltage potential is generated when the measurement end of the thermocouple is at a different temperature than the reference end of the thermocouple. The magnitude of the voltage potential is related to the temperature difference. Therefore, temperature can be determined by measuring the differences in potential created at the junction of the two wires.

Specifications

Type Chromel-Constantan
Typical Output 60 μV/°C
Accuracy Refer to the热电偶测量section in the data logger manual.
Diameter 0.0762 mm (0.003 in.)
Length 36.8 cm (14.5 in.)
Plug Dimensions 1.8 x 3.3 x 1.0 cm (0.7 x 1.3 x 0.4 in.)
Weight 45 g (2 oz)

Compatibility

Note:The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Data Loggers

Product Compatible Note
21X.(retired)
CR10(retired)
CR1000(retired)
CR1000X The CR1000X is compatible when used with the CDM-A108 or CDM-A116.
CR10X(retired)
CR200X(retired)
CR206X(retired)
CR211X(retired)
CR216X(retired)
CR23X(retired)
CR3000
CR500.(retired)
CR500.0(retired)
CR510(retired)
CR6 The CR6 is compatible when used with the CDM-A108 or CDM-A116.
CR6
CR800
CR850
CR9000(retired)
CR9000X(retired)

Additional Compatibility Information

Data Logger Considerations

The thermocouple connects to the data logger via the FWC cable. One differential analog input per sensor is required.

Reference Temperature Measurement

A reference temperature measurement is required. Options for measuring the reference temperature include:

  • Thermistor built into the CR800, CR850, CR1000, CR3000, or CR5000 wiring panel
  • PRT built into the wiring panel of the CR9050 or
  • CR9051E input module for the CR9000X Measurement and Control Datalogger
  • PRT内置于CR7测量和控制数据记录器的CR723T输入卡的接线面板中
  • CR10xtcr热敏电阻连接到CR10x接线面板

Carrying Case

The FW/ENC Carrying Case is required to ship our FW3 thermocouples. It holds up to four thermocouples. Thermocouples returned to Campbell Scientific for repair without this case will be shipped to the customer in a new case and the account charged accordingly.


经常问什么estions

Number of FAQs related toFW3:2

  1. Most Campbell Scientific data loggers can measure a thermocouple without any external signal conditioning. Therefore, a dedicated module is not required.

  2. No. The fine-wire thermocouples were designed to measure ambient air temperature.