由Wedgewood Analytical制造的CSIM11-ORP测量液体的氧化还原电位(ORP)。它可以浸入水中或插入坦克,管道和开放通道中。CSIM11-ORP适用于非压力系统,并不适用于30 psi以上的应用。请联系Campbell Scientific,以获取适用于加压管中安装的探针的建议。
Read MorePlease note that this product has a six-month warranty.
The "-L" on a product model indicates that the cable length is specified at the time of order.
The CSIM11-ORP is similar to the CSIM11, but includes a 0.2-in. platinum band wrapped around the glass electrode, which allows the CSIM11-ORP to respond to the electron density in the fluid. It has a plunger-style pH glass electrode that allows the CSIM11-ORP to be mounted at any angle. The probe's porous polytetrafluoroethylene (PTFE) liquid junction is less susceptible to clogging as compared to conventional reference junctions.
A titanium ground rod runs inside the PPS outer body to eliminate ground loop errors. An internal amplifier boosts the signal, decreasing signal interference. The amplifier is powered by two internal lithium batteries, and thus does not require any current from the data logger. These batteries are designed to last the lifetime of the probe.
The reference solutions and bulb configuration are optimized for natural water applications. Alternate reference solutions and bulb configurations are available. Contact Campbell Scientific for pricing and availability.
Note:CSIM11-ORP使用玻璃灯泡技术,其预期寿命约为6个月至2年,具体取决于水的状况。
Output | Analog |
ORP Range | -700至+1100 mv |
Operating Temperature Range | 0°至80°C |
压力范围 | 0至30 psig |
准确性 | ±0.1% (over full range) |
Impedance | <1 mohm(@ 25°C) |
Reference Cell | Single Junction KCl/AgCl |
身体材料 | ABS |
Wetted Materials | ABS, polytetrafluoroethylene (PTFE), Viton, glass, titanium |
Cable Jacket Material | 聚氨酯 |
响应时间 | 95%的阅读(10 s) |
Drift | < 2 mV per week |
内部锂电池寿命 | 5 years (life of probe) |
直径 | 3.0 cm (1.2 in.) |
Length | 17.8 cm (7.0 in.) |
Weight | 0.5千克(1磅),有4.57-m(15英尺)电缆 |
Note:以下显示了显着的兼容性信息。这不是所有兼容或不兼容产品的全面列表。
Product | Compatible | Note |
---|---|---|
21x(retired) | ||
CR10(retired) | ||
CR1000(retired) | ||
CR10X(retired) | ||
CR200X(retired) | ||
CR206X(retired) | ||
CR211X(retired) | ||
CR216X(retired) | ||
CR23X(retired) | ||
CR295X(retired) | ||
CR300 | ||
CR3000(retired) | ||
CR310 | ||
CR350 | ||
CR500(retired) | ||
CR5000(retired) | ||
CR510(retired) | ||
CR6 | ||
CR800 | ||
CR850 | ||
CR9000(retired) | ||
CR9000X(retired) |
The CSIM11-ORP requires one differential analog input channel.
Number of FAQs related toCSIM11-ORP-L:3
展开全部全部收缩
Most Campbell Scientific sensors are available as an –L, which indicates a user-specified cable length. If a sensor is listed as an –LX model (where “X” is some other character), that sensor’s cable has a user-specified length, but it terminates with a specific connector for a unique system:
If a sensor does not have an –L or other –LX designation after the main model number, the sensor has a set cable length. The cable length is listed at the end of the Description field in the product’s Ordering information. For example, the 034B-ET model has a description of “Met One Wind Set for ET Station, 67 inch Cable.” Products with a set cable length terminate, as a default, with pigtails.
如果电缆用特殊的连接器终止于唯一系统,则型号的末端指定了哪个系统。例如,034B-ET模型将传感器指定为ET107系统的034B。
并非每个传感器都有不同的电缆终止选项。可以通过在传感器产品页面的订购信息区域的两个地方查看特定传感器的选项:
如果在–ET,–ETM,–LC,–LQ或–QD版本中提供传感器,则该选项的可用性反映在传感器型号中。例如,034b以034b-et,034b-etm,034b-lc,034b-LQ和034b-qD提供。
如果有的话,所有其他电缆终止选项均在传感器产品页面的“电缆终止选项”下的“订购信息”页面上列出。例如,如034B-L产品页面的订购信息区域所示,使用–CWS,–PT和–PW选项提供034B-L风集。
Note:As newer products are added to our inventory, typically, we will list multiple cable termination options under a single sensor model rather than creating multiple model numbers. For example, the HC2S3-L has a –C cable termination option for connecting it to a CS110 instead of offering an HC2S3-LC model.
Many Campbell Scientific sensors are available with different cable termination options. These options include the following:
Note:The availability of cable termination options varies by sensor. For example, sensors may have none, two, or several options to choose from. If a desired option is not listed for a specific sensor, contact Campbell Scientific for assistance.
We've updated our privacy policy.Learn More