The CS240DM is a best-in-class smart sensor with a rugged, surface-mountable platinum resistive thermometer (PRT) that measures back-of-module temperature on solar photovoltaic (PV) panels. The CS240DM includes a new Campbell Scientific precision analog-to-digital, smart-sensor module that makes back-of-module temperature measurements that are among the most accurate measurements available today.
Read MoreThe CS240DM consists of a PT-1000 Class A PRT encased in an aluminum disk. The disk protects the PRT, particularly during installation when pulled through conduit, and promotes heat transfer from the surface while minimizing convective heat loss to the surroundings. An adhesive tab on the disk fastens the CS240DM to the measurement surface. If the temperature may exceed 70°C, Kapton tape is also required to secure the probe.
The precision analog-to-digital, smart-sensor module is based on the CR1000X. The module design is optimized for the Class A PRT that minimizes self-heating and lead-wire resistance. Measurement electronics are surge protected, include 1200 V isolation, and are environmentally protected with a rugged over-molding featuring an IP65 rating. Data is differentially transmitted in cabling that is well suited for industrial energy applications with excellent noise rejection and high voltage, NEC outdoor, UV, UL, and NEC ratings.
The CS240DM provides PV stakeholders with highly accurate back-of-module temperature—even at long cable lengths—for use in power-performance modeling and simulation of solar energy applications. Back-of-module temperature is critical for any evaluation of effective irradiance and power conversion.
Sensor | Platinum resistive thermometer (PRT) |
System Uncertainty | ±0.3°C |
Disk Material | Anodized aluminum |
Surge Protection | 1200 V isolation |
Supply Voltage of the Sensor | 5 to 30 Vdc |
Power Draw | 15 mA |
Compliance Information |
|
Conforms with Electromagnetic Compatibility Directive | (EMC) |
Conforms with the Restriction of Hazardous Substances Directive | (RoHS2) |
Disk Diameter | 2.54 cm (1.0 in.) |
Overall Probe Length | 6.35 cm (2.5 in.) |
Overmolded Joint Dimensions | 5.72 x 1.12 x 1.47 cm (2.25 x 0.44 x 0.58 in.) |
Weight | 90.7 g with 3.2 m cable (0.2 lb with 10.5 ft cable) |
Sensing Element |
|
Precision | 1000 ohm Class A platinum sensing element (PT-1000) |
Accuracy | ±(0.15 + 0.002t)°C |
Temperature Coefficient of Resistance | TCR = 3850 ppm/K |
Long-Term Stability | 最大Rodrift 0.04% (after 1000 h at 400°C) |
Operating Temperature Range | -40° to +135°C |
Communications |
|
Protocol | Modbus RTU protocol (over RS-485) |
Format | 8 data bits, 1 stop bit, even parity as default (user-configurable) |
Baud Rate | 19,200 bps as default (user-configurable) |
Modbus ID | Last two digits of serial number as default (user-configurable) |
Cable |
|
Description |
|
Jacket Material | Black semi-gloss PVC, UL VW-1 sunlight resistant for outdoor use |
Agency Approvals |
|
Nominal Wire Diameter | 0.61 mm (0.024 in.) |
Number of FAQs related toCS240DM:4
Expand AllCollapse All
Even when three-pt calibration isn’t ordered, when we build the probes, we perform a final test to verify that they are reading within 0.3°C of our calibrated reference sensor at room temperature.
NIST traceability provides an assurance of accuracy. This is especially desirable in accordance with IEC 61724, which is a specification for monitoring solar energy generation that requires calibrated sensors.
A hot spot is caused if a cell in series is under-producing due to shading and gets reversed bias due to the other producing cells. For bifacial modules, as long as the front face is not shaded, all the cells should be producing and covering a small area on the back side and should not cause a severe mismatch.
Yes, it is NIST traceable.
We've updated our privacy policy.Learn More