CS125 Present Weather and Visibility Sensor
Unrivaled Performance
Ideal for transportation applications
weather applications water applications energy applications gas flux and turbulence applications infrastructure applications soil applications

Overview

The CS125 is an infrared forward-scatter visibility and present weather sensor for stand-alone use or with automatic weather stations including those for road, marine, and airport applications. The CS125 has an attached 5 m (16.4 ft) cable and DB9 connector.

Read More

Benefits and Features

  • High performance sensor at a competitive price
  • Sensor design minimizes airflow disruption at measurement volume
  • Simple field calibration using optional calibration kit
  • Low power - suitable for remote application
  • Automatic status check for faults or window contamination
  • Incorporates automatic dew and hood heaters for all-weather operation
  • Type certified for aviation use by the German Meteorological Service, Deutscher Wetterdienst (DWD)

Images

Detailed Description

The CS125 uses the well-established forward scatter system for visibility measurement, using a 42° scatter angle, which gives accurate estimates of Meteorological Observable Range (M.O.R.) for fog and snow.

它能够识别降水粒子的年代cattering properties and fall speeds, and combines this with a temperature measurement to identify the weather type. It has downward-pointing optics that reduce the risk of contamination of the optics and blockage with snow. Interference to the sample volume from the sensor by flow distortion or heat is minimized.

It also provides reliable present weather information in the form of SYNOP codes, including information on the intensity of precipitation. Accumulation can also be reported.

The CS125 uses continuous high-speed sampling to reduce errors during mixed-weather events and events that return intermittent signals, such as rain and hail, while still providing reliable readings during more stable events, such as fog and mist. The CS125 has high immunity to interference from the visible and infrared warning lights used to mark obstructions, such as wind turbines.

The sensor can be set to a lower sampling frequency to save power, if required.

他CS125集成了低功耗露预防aters, as well as higher-power anti-icing heaters for the hoods as standard. These heaters are automatically controlled to ensure operation in all weather, or they can be disabled individually to save power.

The CS125 continuously monitors its own status and will report internal faults and contamination or blockage of the sensor lenses. It also has two user-configurable alarm outputs that can be used to drive audio or visual alarms using solid-state relays.

The CS125 is certified by Deutscher Wetterdienst as suitable for use to control wind turbine obstruction light systems as specified by 506/04, General Administrative Rules for the Identification of Aircraft Obstructions.

Specifications

Operational

Maximum Reported Visibility 75 km (46.6 mi)
Minimum Reported Visibility 5 m (16.4 ft)
Resolution 1 m (3.28 ft)
Outputs Present and past weather: identifies as standard mist, fog, drizzle, freezing drizzle, drizzle and snow, rain, freezing rain, rain and drizzle, rain and snow, and snow. 56 SYNOP present weather codes and associated METAR and NWS present weather codes - hail detection option; past weather code option.
Accuracy
  • ±8% (up to 600 m [1968.5 ft])
  • ±10% (600 to 10,000 m [1968.5 to 32,808.4 ft])
  • ±15% (10,000 to 15,000 m [32,808.4 to 49,212.6 ft])
  • ±20% (above 15,000 m [49,212.6 ft])
Precipitation Detection Sensitivity 0.05 mm/h
Accumulation Reporting Range 0 to 999.9 mm (0 to 39.37 in.)
Accumulation Accuracy ±15% (against factory calibration standards in the laboratory, for liquid precipitation)
Accumulation Resolution 0.1 mm (0.0039 in.)
Rain Intensity Range 0 to 999.9 mm/h (0 to 39.37 in./h)
(The maximum intensity reported is dependent on the mixture of precipitation falling.)
Intensity Accuracy ±15% (against factory calibration standards in the laboratory, for liquid precipitation)
Intensity Resolution 0.01 mm/h (0.00039 in./h)
Operating Temperature Range -25° to +60°C (standard)
Extended Operating Temperature Range -40° to +70°C (This extended version is available as a special. Contact Campbell Scientific for more information.)
Operating Humidity 0 . . . 100%
Operating Wind Speed Up to 60 m/s
Sensor Sealing Rated to IP66
Total Unit Power Less than 3 W while sampling continuously (including dew heaters)

Mechanical

Material Stainless steel and hard-anodized aluminum powder-coated
Mountings Stainless-steel clip on V-bolt mounting to pole with diameter of 32 to 52.5 mm (1.26 to 2.07 in.)
Mounting Pole An optical mounting pole is available to place the sample volume at 1.5 m (4.9 ft), as recommended by the WMO.
Frangible Mast Frangible masts are available to customer requirements to meet ICAO recommendations (typically placing the sample volume at 2.5 m [8.2 ft]).
Visibility Sensor Dimensions 540 x 640 x 246 mm (21.26 x 25.2 x 9.7 in.) including mount
Cable Length 5 m (16.4 ft)
Sensor Weight ~3 kg (6.61 lb) dependent upon mounting system

Electrical

-NOTE- Lower power states can be achieved by less frequent sampling and remote control of heaters.

Optional power supplies with battery backup available.

Connectors in place of flying leads are available.

A low-voltage shutdown level can be set to prevent backup batteries from being damaged.
Electronics Supply Voltage 7 to 30 Vdc
Hood Heater Supply Voltage 24 V (dc or ac)
Hood Heater Power 2 x 30 W (total of 60 W)
Dew Heater Power 2 x 0.6 W (total of 1.2 W)

Interface

Serial Interface RS-232 or RS-485
Serial Data Rates 1200 to 115,200 bps (38,400 bps default rate)
Alarm Outputs 2 x 0 to 5 V outputs, 32 mA (max)

Optical

-NOTE- Lens contamination circuity monitors both the source and detector lenses for contamination/blockage at 1 s intervals.

The sensor can be configured to adjust calibration for low to moderate window contamination.

Light source stability control ensures stable operation through variations in temperature and with sensor aging.

纠正在1 s间隔s.
Emitter Light Frequency 850 nm

Compatibility

Note:The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Data Loggers

Product Compatible Note
21X(retired)
CR10(retired)
CR1000(retired)
CR1000X
CR10X(retired)
CR200X(retired)
CR206X(retired)
CR211X(retired)
CR216X(retired)
CR23X(retired)
CR295X(retired)
CR300
CR3000(retired)
CR310
CR350
CR500(retired)
CR5000(retired)
CR510(retired)
CR800
CR850
CR9000(retired)
CR9000X(retired)

Downloads

CR1000X CS125 example programs v.1 (10 KB)03-18-2020

CR1000X programs that read continuous data and polled data and use the SET, SETNC, and GET commands. The program that uses the SETNC command powers the CS125 hood heaters when needed according to the dew point. A HygroVUE5 Air Temperature and Relative Humidity Sensor provides the measurements used in the dew point calculation.


CS125 and CS120A OS v.13 (156kb)11-22-2019

Campbell Scientific has introduced a new operating system, OS13, for the CS120A visibility sensor and CS125 present weather sensor. It is fully backwards compatible and is easily installed on all CS120A and CS125 sensors (but not older CS120 sensors). OS13 is available free of charge and can be downloaded here or supplied by email on request.

Upgrade to OS 13 is recommended.

Changes to both CS120A and CS125

To optimise user calibrations, OS13 temporarily disables hood heaters during calibration and resumes normal hood functionality once the calibration is complete.

Hood heaters now operate down to the fault alarm levels of -56°C, but will turn off at low temperatures if a thermistor fault is detected.

OS13 better flags DC saturation, which under very bright conditions might occasionally produce a dirty lens alarm.

OS13 has corrected the potential for level 1 dirty window alarms to occur during heavy fog and rain where visibility drops below 10m.

Changes to CS125 only

OS13 contains improved filtering to reduce the occurrence of short duration precipitation reports caused by transient insect activity. The sensor still retains its sensitivity to the detection of precipitation.

Automatic optimisation to differing background light levels reduce the occurrence of erroneous particles reported in bright light.

OS13 includes a software switch to turn off BCFG from the CS125 message output. If triggered by broken fog, the BCFG message could affect AWOS systems. This does not affect the CS120A.


Campbell Viewpoint v.2.1.0.2 (86 MB)10-09-2019

Campbell Viewpoint is viewing software designed to accompany the Campbell Scientific optical sensor range, including the CS135 ceilometer, SkyVUE PRO, SkyVUE 8, SkyVUE 8M, CS120A visibility and CS125 present weather sensors. It is free to download (or via email on request) and use for 100 hours, after which you will need to purchase a key to continue using it.

Version 2.1.0.2

Viewpoint version 2.1.0.2 has introduced our new ceilometer sensors to the list of instruments that can be monitored. This includes the SkyVue PRO, SkyVUE 8 and SkyVUE 8M.

Previous sensors are still available.

Version 2.1.0.2 also includes some minor bug fixes and improvements to the help menu.


Case Studies

central africa: airport weather system
Central Africa: Airport Weather System
Campbell Scientific’s system integrator, AUDIMOBIL LDA, recently upgraded the airport weather system in the S.......read more
utah: upgraded roadside weather stations
Utah: Upgraded Roadside Weather Stations
The Utah Department of Transportation (UDOT) operates a network of roadside weather stations across the......read more
portugal: cloud base and visibility sensors for military aviation
Portugal: Cloud Base and Visibility Sensors for Military Aviation
AUDIMOBIL recently installed an Automatic Weather Station in a Portuguese Military Air Base, to support......read more

Articles and Press Releases


This Product Replaced

Privacy Policy Update

We've updated our privacy policy.Learn More

Baidu