The CS100-QD barometer, manufactured by Setra, measures for a standard barometric pressure range of600 to 1100 hPa (mBar), which is approximately sea level to 12,000 feet. It is mounted inside a RAWS-F or RAWS-P enclosure and wired to the CR1000 wiring panel.
Read MoreThe CS100-QD is a Campbell Scientific version of Setra's model 278 barometer. It uses Setra’s Setraceram capacitive sensor and IC analog circuit to measure barometric pressure.
The CS100-QD is encased in a stainless steel and polyester case fitted with an 1/8 in. barbed fitting for pressure connection. It includes an internal switching circuit that allows the data logger to power the barometer only during measurement, which reduces power consumption.
Pressure Range | 600 to 1100 hPa (mBar) |
Accuracy at 20°C | ±0.5 mb |
Accuracy at 0° to 40°C | ±1.0 mb |
Accuracy at -20° to +50°C | ±1.5 mb |
Accuracy at -40° to +60°C | ±2.0 mb |
Linearity | ±0.4 mb |
Hysteresis | ±0.05 mb |
Repeatability | ±0.03 mb |
Resolution | ±0.01 mb |
Long-Term Stability | ±0.1mb per year |
Response Time | < 100 ms |
Excitation | 9.5 to 28 Vdc |
Current Consumption |
|
Warm-up Time | < 1 s |
Operating Temperature | -40° to +60°C |
Cable Diameter | 0.8 cm (0.3 in.) |
Cable Length | 0.8米(2.5英尺) |
Dimensions | 9.1 x 6.1 x 2.5 cm (3.6 x 2.4 x 1.0 in.) |
Weight | 135 g (4.8 oz) |
The CS100-QD barometer is mounted inside of a RAWS-F or RAWS-P enclosure and wired to the CR1000 wiring panel.