的CR9000XC, a compact version of theCR9000X, holds up to five user-selectable I/O modules. It is a modular, multiprocessor system that provides precision measurement capabilities in a rugged, battery-operated package. It consists of an environmental enclosure, a base system, and a chassis containing slots for the I/O modules.
的CR9000X series is our fastest data logger series, with a measurement rate of 100,000 Hz and a clock speed of 180 MHz, making it ideal for rapid sampling applications.
For the entire list of available I/O modules for the CR9000XC and CR9000X, visit the Other Accessories section of the Ordering Info page for theCR9000XC和theCR9000X.
Campbell Scientific also offers the CR9000X, a larger version, that accepts up to nine I/O modules. For more information, visit theCR9000XProduct Info page.
Read More的CR9000XC's base system includes a CR9032 CPU module, CR9041 A/D module, CR9011 power supply module, and 128-Mbytes SDRAM memory for program and data storage. The CR9000XC's internal battery has a 7-Ahr capacity.
A mix of I/O modules is selected based on the measurements required for the application. Campbell Scientific offers a large variety of modules. Individual I/O modules can be swapped out, allowing the system to be reconfigured if requirements change.
I/O modules whose model numbers end in an E (e.g., CR9051E, CR9055E) and the CR9052DC include an easy connector module. Easy connector modules allow sensor wiring to remain connected while the input module’s measurement electronics and the rest of the data logger system are used elsewhere.
的CR9000XC includes a non-corrosive, sealed, aluminum enclosure that provides protection from water, dust, and most environmental pollutants.
In August 2004, the CR9000XC replaced the CR9000C. The CR9000C and CR9000XC dataloggers differ in their CPU Module; the CR9000C datalogger uses the CR9031 and the CR9000XC datalogger uses the CR9032.
The CR9032 CPU module supports a measurement rate of up to 100,000 Hz, provides a 180 MHz clock speed, and adds a built-in RS-232 port, 10baseT/100baseT port, CS I/O port, and PC-card slot. The built-in ports enable communication without using the special interfaces (e.g., PLA100, TL925, NL105) that were required for the retired CR9000C datalogger. The PC-card slot allows the CR9000XC to store data on a Type I, Type II, or Type III PCMCIA card, or on a CompactFlash® card if an adapter is used.
An existing CR9000C datalogger may be upgraded to a CR9000XC by replacing the CR9031 CPU module with the CR9032 CPU module.
-NOTE- |
|
Operating Temperature Range |
|
Analog Inputs | 28 single-ended or 14 differential per CR9050, CR9051E, or CR9055(E) module |
Pulse Counters | 12 per CR9071 module |
通信端口 |
|
Switched 12 Volt | 1 |
Digital I/O |
|
Analog Voltage Accuracy | ±(0.07% of reading + 4 A/D counts), -25° to +50°C |
ADC | 16位 |
电源要求 | 9.6 to 16 Vdc |
Communication Protocols | SDM |
Warranty | 3 years |
Dimensions | 25.4 x 27.9 x 22.9 cm (10 x 11 x 9 in.) |
Weight | 12.3 kg (27 lb) with modules |
Note:The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.
Product | Compatible | Note |
---|---|---|
LoggerNet | Version 2.0 or higher | |
PC200W(retired) | ||
PC400 | 1.0版或更高版本 | |
RTDAQ | 1.0版或更高版本 | |
Short Cut | ||
VISUALWEATHER | Version 2.0 or higher |
客户可以将CR9000XC数据量度添加到包含较旧的CR9000或CR9000C Datalogger的网络中。除CR9080以外的I/O模块可以与CR9000系列或CR9000X系列一起使用。CR9000系列通信接口(即NL105,BLC100,TL925,PLA100)与CR9000XC不兼容,因此已退休。RTDAQ软件与旧的CR9000(C)不兼容。客户可以通过使用现代CR9032C CPU模块替换CR9000C的CR9031 CPU模块来升级CR9000C Datalogger到CR9000XC数据词架。
With several channel types, the CR9000XC is compatible with many sensors, including thermocouples and 4 to 20 mA sensors.
Measurement and control peripherals typically used with the CR9000XC are our AM25T 25-Channel Solid State Multiplexer, SDM-CAN Interface, SDM-INT8 Eight Channel Interval Timer, and SDM-SIO4 Serial Input/Output Module. Other measurement and control peripherals are compatible but they do not support the CR9000XC datalogger's maximum measurement rate and are therefore impractical for most CR9000XC applications.
的CR9000XC typically communicates with a PC via direct connect or Ethernet. Because the CR9000XC has an on-board 10baseT/100baseT port, an Ethernet interface such as the NL100 is not required.
使用PC或CompactFlash卡可以增加存储容量。CR9000XC的PCMCIA卡插槽支持I型I,II型或III型PC卡或CF1适配器和一张CompactFlash(CF)卡。
II型卡的存储容量超过1 GB。III型卡提供超过1 GB的数据存储能力,但可能不适合所有环境。Campbell Scientific提供的CF卡最多可存储2 GB的数据。请注意,PCMCIA和CMPACTFLASH卡必须是工业级,并且存储容量为2 GB或更少。
其他通信外围设备是兼容的,但它们不支持CR9000XC Datalogger的最大测量率,因此对于大多数CR9000XC应用程序都是不切实际的。
的CR9000XC includes a non-corrosive, sealed, aluminum enclosure that provides protection from water, dust, and most environmental pollutants.
CRBasic, the CR9000XC's full programming language, supports simple or complex programming and many on-board data reduction processes. CRBasic is included in RTDAQ, LoggerNet, and PC400.
RTDAQ Real-Time Data Acquisition Software must be ordered separately; the CR9000XC is also compatible with other Campbell Scientific software.
Number of FAQs related toCR9000XC:37
展开全部全部收缩
的CR9000X and CR9000XC differ only in the number of I/O cards they can hold. The CR9000X can hold 9 I/O cards, and the CR9000XC can hold 5 I/O cards. We provide both sizes to accommodate our customers; the same I/O cards can be used in either chassis.
The maximum cable length depends on the interface being used.
Yes. The simplest method is to use conditional program statements that execute most of the code based on time. For example, the data could be scheduled to log at 6 a.m. and finish at 8 p.m. using CRBasic instructions such asTimeIntoInterval(). Another option is to use anIfThen/EndIfconstruction that does a logical test of light-level measurements based on a light sensor. An additional option is to use calculated sunrise and sunset times along with a combination ofRealTime()和Caseinstructions.
For more information, see the “Decisions, Decisions, Decisions…” article.
If small amounts of data are transferred per transmission, it will not be a problem. Larger amounts of data can overrun buffers in the modem, causing lost data. In that situation, lower the baud rate on the data logger to avoid the issue.
Common causes include the following:
The data logger will not reset the SW12 unless it is done under program control using theSW12()或者portset()instructions, or unless the data logger compiles or recompiles a program. This could be done when a new program is sent to the data logger, or if the power is cycled.
可以对数据记录器进行编程以通过使用SendVariables()或者ModemCallback()instruction in CRBasic.
注意:CR200X操作系统中不支持这些说明。
No, because it would not work. The SC32B is used to do the following:
Yes. Both the RavenXTV (Verizon) and the RavenXTG (AT&T) are available.
We've updated our privacy policy.Learn More