Services Available | |
---|---|
Repair | 不 |
Calibration | 不 |
免费支持 | 不 |
2005年9月,CR205 Datalogger被CR206 Datalogger取代。CR206具有提高的沟通能力。CR205可以在CR206(X)网络中使用,但是CR206(X)需要处于透明模式。有关详细信息,请联系我们的一位应用工程师。
A/D Converter | 12 bit |
扫描率 | 每秒一次(最大) |
Single-Ended Analog Channels | 5 (individually configured) |
Analog Voltage Range | 0 to +2500 mV |
Measurement Resolution | 0.6 mV |
Excitation Channels | 2(适用于+2.5或+5伏的编程) |
Switched Battery Port | 1 |
脉冲计数通道 | 2 |
Control Ports | 2 |
Battery Voltage Range | 7 to 16 Vdc |
Communications | RS-232 |
不te:以下显示了显着的兼容性信息。这不是所有兼容或不兼容产品的全面列表。
Product | Compatible | 不te |
---|---|---|
014A-L | ||
03002-L | ||
034b-l | ||
05103-45-L(retired) | ||
05103-L | ||
05106-L(retired) | ||
05305-L | ||
107 | ||
108 | ||
109 | ||
109SS-L | ||
110PV-L(retired) | ||
237-L | ||
255-100 | ||
27106T-L | ||
43347-L | ||
52202-L | ||
CMP11-L | ||
CMP21-L | ||
CMP6-L | ||
CS100 | ||
CS106 | ||
CS15-L(retired) | ||
CS215-L(retired) | ||
CS300-L(retired) | ||
CS410-L(retired) | ||
CS431-L(retired) | ||
CS450-L(retired) | ||
CS455-L(retired) | ||
CS460-L(retired) | ||
CS470(retired) | ||
CS471(retired) | ||
CS475A-L | ||
CS475-L(retired) | ||
CS511-L | ||
CS525-L(retired) | ||
CS616 | ||
CS625(retired) | ||
CS650 | ||
CS700H-L | ||
CS700-L | ||
CSAT3(retired) | ||
CSIM11-L | ||
CSIM11-ORP-L | ||
ENVIROSCAN(retired) | ||
HMP45C-L(retired) | ||
HMP60-L | ||
LI190SB-L(retired) | ||
LI200X-L(retired) | ||
LWS | ||
OBS-3+(retired) | ||
OBS300(retired) | ||
SEN12512(retired) | ||
SR50A-L | ||
TB4-L | ||
TB4MM-L | ||
TE525-L | ||
TE525mm-L | ||
TE525WS-L | ||
Windsonic1-L | ||
WINDSONIC4-L | ||
WXT520(retired) |
Product | Compatible | 不te |
---|---|---|
LoggerNet | Version 2.1 or higher | |
PC200W(retired) | ||
PC400 | 1.0版或更高版本 | |
pconnect(retired) | 版本3.0或更高版本 | |
pconnectCE(retired) | Version 2.0 or higher | |
Short Cut | ||
VISUALWEATHER | 版本2或更高版本 |
CR205内部扩频电台可以交易nsmit data to other CR205 loggers or RF400 radios. It can also communicate with CR206(X) loggers, RF401 radios, or RF430 radios if they are set to the transparent mode. Certain CR205 settings must match the radio's settings for communications between the data logger and radio to be successful. The factory default settings of these devices might not match; therefore, they may need to be reconfigured before communications can take place.
The CR205 can communicate with a PC via direct connect, NL100 Ethernet interface, MD485 multidrop modem, and digital cellular modems. Data can be viewed on the CD295 DataView II display, Archer-PCon Field PC, or a user-supplied PDA (PConnect or PConnectCE software required).
The CR205 is not compatible with SDM devices and multiplexers.
CR205可以测量各种传感器,包括SDI-12传感器和4至20 mA传感器。它不能进行差异测量,并且与冰冻林/冰,燃料湿度/温度,地理位置,当前天气,土壤热通量,土壤矩阵潜力以及我们的价格清单上列出的应变传感器不兼容。
具有最小功率要求的应用程序可以使用ENC200机箱容纳数据记录器和#16869密封可充电电池。ENG200不能容纳大于#16869的晴雨表或电池。但是,对于大多数基于CR205的系统,ENC10/12或ENC12/14的外壳都足够了。
The CR205 uses an external power supply and has a built-in regulator. When connected to the on-board charging circuit, the sealed rechargeable battery should be 7 Ahr or smaller. Using larger batteries with the data logger's built-in charger may result in excessive PC board heating. This is especially a concern when the battery is deeply discharged or failing with a shorted cell. Campbell Scientific also recommends that solar panels be 10 W or less and wall chargers be 1 A or smaller.
支持Modbus通信和SDI-12传感器的特殊操作系统。还包括CR2XX Datalogger的编译器和CRBASIC编辑器支持文件。
使用此文件将更新数据logger compiler andCRBasic Editor支持文件。
不te: Not to be used with the CR200X series.
Includes: MODBUS Instructions, SDI12Sensor, WindVector
排除:Goes说明,序列显示,ETO,Senddata和LoggerIdentify
Special operating system that supports serial sensors, SDI-12 sensors, and sending data to another PakBus device. Also included is the Compiler and CRBasic Editor support files for the CR2xx dataloggers.
使用此文件将更新数据logger compiler andCRBasic Editor支持文件。
Includes: SerialInput, SendData, SDI12Sensor, WindVector
Excludes: GOES Instructions, ETo, MODBUS Instructions, LoggerIdentify
一种用于下载操作系统并设置坎贝尔科学硬件的软件实用程序。如果坎贝尔科学软件包先前安装了Pakbus图和网络计划者,也将更新它们。
支持的操作系统:
Windows 11, 10, 8.1, 8, and 7 (Both 32 and 64 bit)
Short Cut creates simple programs for our CR200-series, CR300-series, CR510, CR500, CR10(X), 21X, CR23X, CR6, CR800, CR1000(X), CR3000, CR5000, CR9000X and GRANITE dataloggers. Both mixed array and table data operating systems are supported. Short Cut also supports our ET106, ET107 and MetData1 weather stations. The newest version includes the latest sensor files.
Default operating system loaded into the datalogger at the factory. Also included is the Compiler and CRBasic Editor support files for the CR2xx dataloggers.
使用此文件将更新数据logger compiler andCRBasic Editor支持文件。
Includes: ETo, WindVector, LoggerIdentify
Excludes: GOES Instructions, SDI12Sensor, SerialInput, MODBUS Instructions, SendData
Number of FAQs related toCR205:3
Expand All全部收缩
The CR200X-series and the retired CR200-series dataloggers are NOT compatible with SDMs or multiplexers. If more channels are needed or may be needed in the future, consider purchasing a CR800, CR850, or CR1000 instead.
CR200系列Datalogger的独特之处在于它与其他Campbell Scientific Data Loggers没有车载程序编译器。这意味着CRBASIC文件(*.cr2)必须首先在计算机上编译,然后必须将编译的二进制文件(*.bin)发送到数据记录器。当在CRBASIC中创建程序时,最后一步是编译文件,因此创建程序bin文件。
编译器用于生成bin文件的编译器与数据记录器中的操作系统版本匹配,这一点非常重要。如果将bin文件发送到数据记录器,并且编译版本与当前OS不匹配,则程序发送将失败,并且将显示“错误的OS版本”消息。
为了避免OS版本不匹配问题,如果选择CR2文件作为要下载到数据记录器的文件,LoggerNetversion 2.1b and greater will first query the data logger for its OS version and then attempt to find the matching compiler in theLoggerNet程序文件目录(默认情况下,这是C:\Program Files\Campbellsci\LoggerNet). If the matching compiler exists,LoggerNetwill compile the file and send that file to the data logger. Note that if the *.bin file is chosen,LoggerNetwill not compile the file before sending it.
The software CD that is shipped with each CR200-series datalogger contains the appropriate compiler for the data logger OS. Copy this file into theLoggerNetprogram files directory so that it is available for use byLoggerNet。在CRBASIC中,选择此文件作为编译器中使用的编译器Options | Supported Loggers菜单项。
实际的最大值是在数据记录器上的每两个控制终端连接一个多路复用器。可以在多路复用器之间共享控制终端以增加连接的多路复用器的数量。但是,共享终端需要更复杂的接线和编程。建议每两个控制终端连接多个多路复用器的用户与Campbell Scientific的销售或支持工程师联系以寻求帮助。