The CR10X-2M stored up to 1,000,000 data points.
The CR10X-2M provided sensor measurement, timekeeping, data reduction, data/program storage and control functions. Data and programs were stored either in a nonvolatile Flash memory or RAM. A lithium battery backed up the RAM and real-time clock. The CR10X-2M also suspended execution when primary power (BPALK, PS100) dropped below 9.6 V, reducing the possibility of inaccurate measurements.
Read MoreThe CR10X-2M stored up to 1,000,000 data points. The data logger consisted of a CR10XM-2M Measurement and Control Module and black CR10X Wiring Panel.
The CR10X-2M provided sensor measurement, timekeeping, data reduction, data/program storage and control functions. Data and programs were stored either in a nonvolatile Flash memory or RAM. A lithium battery backed up the RAM and real-time clock. The CR10X-2M also suspended execution when primary power (BPALK, PS100) dropped below 9.6 V, reducing the possibility of inaccurate measurements.
从我们的定价体系o CR10X-2M被移除n 19 April 2007.
Memory | 多达1,000,000个数据点 |
Analog Inputs | 12个单端或6个差异(单独配置) |
脉冲计数器 | 2 |
切换电压激发 | 3 |
Control/Digital Ports | 8 |
串行I/O端口 | 1 |
扫描率 | 64 Hz |
Burst Mode | 750 Hz |
模拟电压分辨率 | To 0.33 µV |
A/D Bits | 13 |
Programming | Edlog |
Data Storage | 混合阵列,表格 |
电信 | PakBus, Modbus, Alert |
A typical field-based CR10X-2M system included:
Execution of this download installs the CR10X Operating System (Mixed-Array) on your computer.
不te: The Device Configuration Utility is used to upload the included operating system to the datalogger. Requires an SC32A or SC32B.
Execution of this download installs the CR10X Table Data Operating System on your computer.
不te: The Device Configuration Utility is used to upload the included operating system to the datalogger. Requires an SC32A or SC32B.
此下载的执行将在计算机上安装CR10X PAKBUS操作系统。
不te: The Device Configuration Utility is used to upload the included operating system to the datalogger. Requires an SC32A or SC32B.
A software utility used to download operating systems and set up Campbell Scientific hardware. Also will update PakBus Graph and the Network Planner if they have been installed previously by another Campbell Scientific software package.
支持的操作系统:
Windows 11、10、8.1、8和7(32位和64位)
Number of FAQs related toCR10X-2M:9
展开全部全部收缩
CR10X具有电池背面的RAM和时钟。换句话说,如果丢失了交流电源,则程序,最终存储数据或时钟设置不会丢失。数据通过内部程序发送到最终存储。可以使用指令96活动串行数据输出来通过内部程序从最终存储到存储模块,计算机或打印机发送数据。
The CR1000 can send data to the Internet using GPRS.
The CR10X uses downloadable operating systems instead of PROMs and includes more instruction in the standard operating system. For a list of instructions included in the standard operating system,refer to theprompt sheet orCR10X manual.
是的。可以使用Modbus协议直接从CR10X获得数据。数据记录器必须安装一个Modbus操作系统。最初可以使用数据记录仪购买Modbus操作系统,也可以与Modbus OS联系Campbell Scientific进行改造CR10X。参考13619 CD页面上的CR10X Modbus操作系统.
获得数据的替代方法是使用OPC。我们的Loggernetand PC-OPC software are needed. The version of Wonderware must also work with OPC.
如果CR10X具有Modbus OS,则可以使用Wonderware显示数据。没有modbus OS,Loggernetsoftware would be needed to collect the data and then the PC-OPC Sever software would be used to display the data.
Instruction 15, Control Port Serial I/O, does allow the use of one control port for hardware flow control (RTS/DTR) or (TXD/RXD). The first control port is the (RTS/DTR) line. Baud rate is limited to 300 or 1200.
Data can be sent out the CS/IO port automatically using Instruction 96 Activate Serial Data Output.
The CR510, CR500, CR10X, CR23X, CR800, CR850, CR3000, and CR1000 can be used for Modbus applications.
The CR510, CR500, and CR10X require a special operating system. Purchase an operating system with the Modbus protocol, and download it to the data logger using CSOS downloading software or the DevConfig Utility.
Modbus protocol is standard in the CR23X, CR800, CR850, CR3000, and CR1000.
A practical maximum is to connect one multiplexer per every two control terminals on the data logger. Control terminals can be shared between multiplexers to increase the number of connected multiplexers. Sharing terminals, however, requires more complex wiring and programming. Users who would like to connect more than one multiplexer per every two control terminals are advised to contact a sales or support engineer at Campbell Scientific for assistance.