The CE4 is a current-excitation module that applies a constant current to the heating element of up to four 229 Heat Dissipation Water Matric Potential Sensors. A current-excitation module is required when you use 229 sensors to measure soil water matric potential.
阅读更多CE4电流激励模块可以向229的加热元件提供恒定电流。CE4源电流最多可达四个229s。该模块需要12个VDC电源。通过将CE4连接到一个或多个AM16 / 32系列多路复用器,可以通过一个数据记录器测量的229个传感器的数量。最多四个多路复用器可以连接到CE4。
笔记:The CE4 module switches currents that are greater than 30 mA, which degrades the contact surfaces of the mechanical relays. Therefore, the multiplexer channels to which the CE4 have been connected may become unsuitable for other applications. (Refer to the multiplexer manual for more information.)
输出 | 50 mA±0.25 mA(调节) |
输出Channels | 4. |
力量 | 需要12个VDC源 |
主动电流消耗 | 25 mA + (50 mA) x (number of 229s connected to the CE4) |
方面 | 11.5 x 5.4 x 2.7 cm (4.5 x 2.1 x 1.1 in.) |
Weight | 131 g (4.6 oz) |
笔记:下面显示了显著的兼容性备用ion. It is not a comprehensive list of all compatible or incompatible products.
产品 | 兼容的 | 笔记 |
---|---|---|
21X(退休) | ||
CR10(退休) | ||
CR1000.(退休) | ||
CR1000X. | ||
CR10X.(退休) | ||
CR200x.(退休) | ||
CR206x.(退休) | ||
CR211x.(退休) | ||
CR216X(退休) | ||
CR23X(退休) | ||
CR295X(退休) | ||
CR300. | ||
CR300.0(退休) | ||
CR310 | ||
CR350 | ||
CR500(退休) | ||
CR5000.(退休) | ||
CR510(退休) | ||
CR6 | ||
CR800 | ||
CR850 | ||
CR9000(退休) | ||
CR9000X(退休) |
产品 | 兼容的 | 笔记 |
---|---|---|
ENC10 / 12. | ||
ENC10 / 12R. | ||
ENC12 / 14. | ||
ENC14/16 | ||
enc16 / 18. |
Cable3cbl可用于将CE4连接到数据记录器(请参阅订购信息)。
The CE4 requires 12 Vdc power. A data logger control port is typically used to activate the module. When the control signal is received, all 4 channels output a 50 mA source current to the connected loads (typically 229 probes). When the control signal is dropped to 0 Vdc, output from the module ceases.
有效时,12 V电源所需的电流大致如下:
25 mA +(50 mA)(连接到CE4输出的229个传感器的数量)。
CE4可以直接源四个探针的电流。在需要更多传感器的应用中,CE4的输出可以连接到多达四个AM16 / 32B多路复用器,大大扩展系统容量。
当使用多路复用器时,用户应该知道,大于30 mA的切换电流将降低机械继电器的接触表面。这将对这些继电器的适用性产生不利地影响多重低压信号。尽管以这种方式使用的继电器不再有资格进行低电压测量,但它继续用于切换超过30mA的电流。因此,建议用户记录哪些多路复用器信道用于多路复用器通道对229-L探针复用50 mA激励,以避免使用这些通道进行未来应用中的低电压测量。
The CE4 requires a desiccated, non-condensing environment; a Campbell Scientific enclosure is recommended. The CE4's case has mounting flanges for attachment to the 1"-on-center hole grid of Campbell Scientific enclosures. Grommets and screws are provided to attach the flanges to the backplate of our enclosures.
与之相关的常见问题解答数量CE4.:7.
Expand AllCollapse All
The CE4 and CE8 have CMOS circuitry controlled by a 0 to 5 Vdc analog signal provided by a data logger control port.
可以使用以下等式计算有源电流漏极:
Current drain = 25 mA + (50mA) x (number of 229-L sensors connected to the CE4 or CE8)
例如,使用3个传感器的CE4的当前漏极计算如下:
电流漏极= 25 mA +(50 mA)x(3个传感器)= 25 mA + 150 mA = 175 mA。
虽然这可以在±2500 mV范围内的最大电阻为50欧姆,但在±5000 mV范围内100欧姆,这不是确定电阻的最佳方法。用于测量未知电阻的优选方法是使用数据记录器激励通道。电流激励通道可与CR3000一起使用。具有半桥或全桥电路的模拟励磁通道可用于其他数据记录器。有关详细信息,请参阅具体数据记录器手册
Campbell Scientific建议使用Cable3CBL-L,22 AWG电缆,带有三根导体和排水线。但是,任何类型的铜线之间的18 AWG和22 AWG可用于控制CE4 / CE8。
CE4和CE8是恒定电流装置,旨在在每个通道上产生50 mA的电流。在欧姆法律之后,电压输出将随着连接负载的电阻而变化:
V.出去= 0.05 A/RL.其中V.出去生产在伏特和rL.是欧姆载荷的电阻。
CE4和CE8是恒定电流装置,设计成为229-L水上型电位传感器产生恒定电流。有关详细信息,请参阅229-L产品页面。