Get to Know Your Data Logger’s Spare Tire: The Lithium Battery

byJacob Davis| Updated: 05/18/2016 | Comments: 0

Tags

Battery

Search the Blog


Subscribe to the Blog

Set up your preferences for receiving email notifications when new blog articles are posted that match your areas of interest.


Area / Application

Product Category

Activity

Corporate / News

Enter your email address:



Suggest an Article

Is there a topic you would like to learn more about? Let us know. Please be as specific as possible.

Leave this field empty

spare lithium battery and datalogger

When was the last time you checked the air pressure on your automobile’s spare tire? What if you were driving along, got a flat tire, and discovered that your spare tire was flat as well? We don’t often think about our spare tire until we need it, and the same may be true for our data logger’s spare battery. Your Campbell Scientific data logger has a spare battery to protect your data. This backup battery should be periodically checked so you don’t end up stranded in the field without your data.

Since the release of the CR10X, Campbell Scientific data loggers have included an internal lithium backup battery. When the data logger is disconnected from 12 volts main power, the lithium battery maintains the data logger clock and data. When the data logger is reconnected to 12 volts, it seamlessly begins logging data again.

Note:Data loggers such as theCR300, which use flash memory for data storage, do not require a lithium battery for data protection. A lithium battery, however, is still present for maintaining the clock time.

How often is the lithium battery voltage measured by the data logger?

The lithium battery voltage is measured by the data logger once per day, and the value is held in theStatustable. TheCR300,CR310, and CR200X-series dataloggers are exceptions, as they do not measure this voltage.

推荐的佛r You:Review the "Connect Window Tutorial."

What is normal battery voltage?

Typically, the voltage is extremely stable if the data logger is powered from another source and its temperature is stable. A new internal battery supplies approximately 3.6 Vdc, and it should be replaced when its reading is at or below 2.7 Vdc.

What happens if the lithium battery voltage gets too low?

When the voltage is below 2.7 volts and the main power supply is removed, there is a risk that you could lose data, the program, and the clock setting. When the lithium battery voltage is below approximately 2 volts, your data logger operation may be affected—even with the main power supply connected. Regardless of the reliability of the main power supply, depleted lithium batteries should be replaced.

How long does a lithium battery typically last?

Under ideal conditions, the internal battery in aCR1000orCR6datalogger typically lasts three years. Conditions such as the RAM being full or temperature extremes can significantly shorten this time.

Tip:You may be able to lengthen the battery life expectancy past five years by using a continuous connection to a main power supply.

What can I do to ensure the lithium battery is ready when I need it?

The following are some tips to help ensure that you aren’t stranded without your data:

  • When you store your data loggers, leave them connected to 12 volts power. If you have a CR6 datalogger, use the Disable Lithium Battery setting.
  • 检查锂电池电压作为常规标准t of every site visit you do. (Remember, this is not possible with CR300- and CR200X-series dataloggers because they do not measure this voltage.)
  • Replace the batteries on a routine schedule. The frequency of battery replacement depends on the station locations, but five years is common.
  • Send your data loggers in for routine calibration. Any lithium battery older than 12 months is replaced as part of the calibration service performed by Campbell Scientific. (Contact our Service Departmentif you wish to arrange sending in a data logger for calibration.)

How do I replace an internal lithium battery?

Internal lithium batteries are user replaceable. You can find the instructions in the manual for the specific data logger.

How do I know which battery is the right one for my data logger?

Below are some links to help you quickly find which battery you need:

Data Logger Battery Needed

CR6,CR1000X

pn 30028 (3.6 Vdc, 2.4 Ah, AA size cell)

30028 battery

CR1000,CR800,CR850,CR3000

pn 13519 (3.6 Vdc, 1.2 Ah, ½ AA size cell)

13519 battery

CR300,CR310, CR200X-series,CRVW3

pn 15598 (3 V coin cell CR2025)

15598 battery

CR10X,CR510,CR9000X,CR9000

pn 8025 (3 V coin cell 24 mm CR2430)

8025 battery

CR5000

pn 13497 (3.6 V 1.65 Ah 2/3 AA size cell)

13497 battery

These batteries are standard sizes, and you may be able to purchase one locally. If you choose to purchase your battery from a third-party vendor, be sure to select a high-quality battery for better performance.

If you have any lingering questions about internal batteries, feel free to post a comment below.I checked the lithium battery voltage on my data loggers. Now, I need to go check the air pressure on my spare tire.


Share This Article



About the Author

jacob davisJacob Davis is the Technical Support Manager at Campbell Scientific, Inc. He directs a group of talented, experienced technical support engineers. His specialties include serial communications and advanced data logger programming. Jacob has a master’s degree in Hydrology and worked with large irrigation projects before coming to Campbell Scientific, Inc.

View all articles by this author.


Comments

Pleaselog in or registerto comment.

We're active on social media!
Stay informed with our latest updates by following us on these platforms:

Baidu