AL200 Alert2编码器,调制器和传感器接口
警报2Ready
Improved accuracy and performance for flood warning systems
天气应用 水应用 能源应用 气通量和湍流应用 infrastructure applications soil applications

Overview

The AL200 is an ALERT2 encoder and modulator that supports ALERT2 and ALERT-concentration services. It meets the ALERT2 standards maintained by National Hydrologic Warning Council (NHWC) and ALERT Users Group (AUG). ALERT2 improves the accuracy and performance of flood warning systems and software, by providing you with faster data transfer, forward error correction, and a TDMA architecture.

With integrated sensor inputs, the AL200 allows you to create a minimal ALERT2 transmitter/station, decreasing the cost of a typical flood warning system. Combining the AL200 with a Campbell Scientific data logger provides enhanced sensor support, user-defined logic and control, and data logging capabilities.

Note:开发了AL200嵌入式代码的一部分,并由Blue Water Design LLC版权所有,并根据许可使用。

Read More

Benefits and Features

  • Easily configurable with graphical, point-and-click software
  • 在tegrated sensor inputs for greatly reduced station cost
  • Onboard measurement of supply voltage, clock/GPS quality
  • 事件或计划驱动的电池,时钟,小费桶,电压,电流,SDI-12,高/低状态的报告
  • Screw terminals for power, radio, and sensors for easy cabling
  • Easy access test features for transmission, radio power, and alignment

Images

Detailed Description

Channels Available and Their Functions

  • P1:Tipping Bucket / Switch Closure Count Accumulator
  • SE1:Single-ended Analog Input, millivolt or milliamp
  • C1:用于有限的SDI-12或高/低状态的数字
  • SW12:开关供电传感器
  • G:地面

警报2Reporting

When used standalone, the AL200 can generate time and event driven reports for Battery, Clock Status, Tipping Bucket, Analog Input (mV or mA), Digital (SDI-12 or High/Low State).

Specifications

Power Connector Two-wire, 0.15-in. pitch removable terminal (reverse polarity protected)
电源要求 9 to 18 Vdc
配置 Device Configuration Utility over USB (settable modulation levels using Device Configuration Utility)
LED GPS,串行,无线电(RS-232和CS I/O共享串行活动LED。)
CS I/O Port SDC 7, 8,10, or 11 (multiplexed with on-board sensor interface)
RS-232端口 DCE
USB Port micro-b
温度范围 -40°至 +60°C
Communication Rate
  • 1200 to 57,600 bps (RS-232 DCE Port)
  • 9600至460.8 kbps(CS I/O端口)
当前排水
  • 1.5 mA (@ 12 Vdc when idle)
  • 40 mA (@ 12 Vdc during GPS fix)
  • 35 MA(传输期间12 VDC)
Timekeeping Setting via GPS ±1μs
Drift ±0.17 s/day (without GPS sync, 40°C temperature change)
Analog Input (SE1) Sensor Interface 0 to 5 Vdc (16-bit ADC; millivolt or 4 to 20 mA selectable)
支持协议 ALERT1 and ALERT2
SMA连接器 Active GPS antenna
Test Button Test transmit and tone
Dimensions 16 x 7.7 x 2.2厘米(6.3 x 3.0 x 0.9英寸)

Sensor Interface

Channels Available Switch closure (P1), single-ended analog (SE1), limited SDI-12 (C1), switched 12 V, ground
Analog input (SE1) 0 to 5 Vdc, 16-bit Adc (millivolt or 4 to 20 mA selectable)

Radio Interface

Channels Available TX,PTT,开关电池,地面
RCFSK Modulation 100至1000 mV,±50 mV(可选软件)

标准

Compliance RoHS and CE
产品标准 EN 61326-1:2013
测试标准
  • IEC 61000-4-2, Electrostatic Discharge Immunity
  • IEC 61000-4-3,辐射RF免疫力
  • IEC 61000-4-4, Electrical Fast Transients Immunity
  • IEC 61000-4-5, Surge Immunity
  • IEC 61000-4-6,进行了RF免疫
  • CIPSR 11, Class B Emission

Compatibility

Note:以下显示了显着的兼容性信息。这不是所有兼容或不兼容产品的全面列表。

Data Loggers

产品 Compatible Note
21x(retired)
CR10(retired)
CR1000(retired)
CR1000X
CR10X(retired)
CR200X(retired)
CR206X(retired)
CR211X(retired)
CR216X(retired)
CR295X(retired)
CR300
CR3000(retired)
CR310
CR350
CR500(retired)
CR5000(retired)
CR510(retired)
CR6
CR800
CR850
CR9000(retired)
CR9000X(retired)

其他兼容性信息

AL200支持Alert1和Alert2协议。

A standalone AL200 can measure:

  • 具有0至5 V或0至20 mA输出的模拟传感器
  • SDI-12 sensors
  • 浮点 /接触开关传感器
  • CS451 and CS456 Pressure Transducers
  • CS475, CS476, and CS477 Radar Water-Level Sensors
  • CS460 Pressure Transducer
  • SR50A声波传感器
  • CS11 AC Current Sensor

下载

Alert2 OS V.5.0(623 KB)10-11-2021

当前的AL200操作系统用于Alert2使用新版本Alert2 2.0 API。需要设备配置实用程序来更新AL200中的操作系统。

Current version includes bug fixes and aligns with the ALERT2 2.0 API. Information on the API commands supported can be found in the included pdf document. This firmware is not recommended for users using ALERT2XX systems or when using the AL200 in stand-alone mode.


AL200 ALERT & ALERT2 OS v.4.0 (612 KB)05-08-2020

Current AL200 operating system for ALERT and ALERT2. Requires the Device Configuration Utility to update the operating system in the AL200.

这些当前版本包括对其先前版本的错误修复和改进,并建议所有用户使用。

Operating System Version
ALERT 1.0
警报2 4.0
查看更新历史记录

警报配置工具v.1.1(47.7 MB)06-30-2016

A software utility used to configure the ALERT210 and AL200.


AL200 USB驱动程序v.2.08.28(1.64 MB)03-05-2013

Windows操作系统的AL200 USB驱动程序。32和64位支持Windows 8,Windows 7,Windows Vista和Windows XP。

注意:在将AL200插入计算机之前,应加载驱动程序。


Case Studies

panama canal: upgraded flood warning system
Panama Canal: Upgraded Flood Warning System
巴拿马运河一直使用过时的水位系统,直到巴拿马运河当局(ACP)......阅读更多
德克萨斯州:哈维飓风
Texas: Hurricane Harvey
在February of 2015, Campbell Scientific was awarded a bid to supply the Harris County......阅读更多
texas: transitioning to alert2
Texas: Transitioning to ALERT2
Alert2是一种现代的通信协议,可以改善....................................................阅读更多

Articles and Press Releases

隐私政策更新

We've updated our privacy policy.Learn More

Baidu